Intravascular ultrasound (IVUS) is an invasive modality which provides cross-sectional images of a coronary artery. In these images both the lumen and outer vessel wall can be identified and accurate estimations of their dimensions and of the plaque burden can be obtained. In addition, further processing of the IVUS backscatter signal helps in the characterization of the type of the plaque and thus it has been used to study the natural history of the atherosclerotic evolution. On the other hand its indigenous limitations do not allow IVUS to assess accurately stent struts coverage, existence of thrombus or exact site of plaque rupture and to identify some of the features associated with increased plaque vulnerability. In order this information to be obtained, other modalities such as optical coherence tomography, angioscopy, near infrared spectroscopy and intravascular magnetic resonance imaging have either been utilized or are under evaluation. The aim of this review article is to present the current utilities of IVUS in research and to discuss its advantages and disadvantages over the other imaging techniques.
引用
收藏
页数:10
相关论文
共 75 条
[1]   A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis -: Results of the restenosis intrastent:: Balloon angioplasty versus elective sirolimus-eluting stenting (RIBS-II) trial [J].
Alfonso, Fernando ;
Perez-Vizcayno, Maria-Jose ;
Hernandez, Rosana ;
Bethencourt, Armando ;
Marti, Vicens ;
Lopez-Minguez, Jose R. ;
Angel, Juan ;
Mantilla, Ramon ;
Moris, Cesar ;
Cequier, Angel ;
Sabate, Manel ;
Escaned, Javier ;
Moreno, Raul ;
Bañuelos, Camino ;
Suarez, Alfonso ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (11) :2152-2160
[2]   Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation - Insights from serial intravascular ultrasound analysis in the TAXUS II study [J].
Aoki, J ;
Colombo, A ;
Dudek, D ;
Banning, AP ;
Drzewiecki, J ;
Zmudka, K ;
Schiele, F ;
Russell, ME ;
Koglin, J ;
Serruys, PW .
CIRCULATION, 2005, 112 (25) :3876-3883
[3]   An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study [J].
Barlis, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. ;
Dimopoulos, Konstantinos ;
van der Giessen, Willem J. ;
van Geuns, Robert-Jan M. ;
Ferrante, Giuseppe ;
Wandel, Simon ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Eerdmans, Pedro ;
Jueni, Peter ;
di Mario, Carlo .
EUROPEAN HEART JOURNAL, 2010, 31 (02) :165-176
[4]   Comparison of intravascular ultrasound and quantitative coronary angiography for the assessment of coronary artery disease progression [J].
Berry, Colin ;
L'Allier, Philippe L. ;
Gregoire, Jean ;
Lesperance, Jacques ;
Levesque, Sylvie ;
Ibrahim, Reda ;
Tardif, Jean-Claude .
CIRCULATION, 2007, 115 (14) :1851-1857
[5]   Incidence, predictors, and outcomes of coronary dissections left untreated after drug-eluting stent implantation [J].
Biondi-Zoccai, GGL ;
Agostoni, P ;
Sangiorgi, GM ;
Airoldi, F ;
Cosgrave, J ;
Chieffo, A ;
Barbagallo, R ;
Tamburino, C ;
Vittori, G ;
Falchetti, E ;
Margheri, M ;
Briguori, C ;
Remigi, E ;
Iakovou, I ;
Colombo, A .
EUROPEAN HEART JOURNAL, 2006, 27 (05) :540-546
[6]   Intravascular ultrasound for the evaluation of therapies targeting coronary atherosclerosis [J].
Bose, Dirk ;
von Birgelen, Clemens ;
Erbel, Raimund .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) :925-932
[7]   Evaluation of intracoronary stenting by intravascular optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Yabushita, H ;
Shishkov, M ;
Kauffman, CR ;
Gauthier, DD ;
MacNeill, BD ;
Houser, SL ;
Aretz, HT ;
Halpern, EF ;
Jang, IK .
HEART, 2003, 89 (03) :317-320
[8]   ANGIOCARE: An automated system for fast three-dimensional coronary reconstruction by integrating angiographic and intracoronary ultrasound data [J].
Bourantas, Christos V. ;
Kalatzis, Fanis G. ;
Papafaklis, Michail I. ;
Fotiadis, Dimitrios I. ;
Tweddel, Ann C. ;
Kourtis, Iraklis C. ;
Katsouras, Christos S. ;
Michalis, Lampros K. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :166-175
[9]   Clinical Indications for Intravascular Ultrasound Imaging [J].
Bourantas, Christos V. ;
Naka, Katerina K. ;
Garg, Scot ;
Thackray, Simon ;
Papadopoulos, Dimitris ;
Alamgir, Farqad M. ;
Hoye, Angela ;
Michalis, Lampros K. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (10) :1282-1290
[10]   In vivo validation of a novel semi-automated method for border detection in intravascular ultrasound images [J].
Bourantas, CV ;
Plissiti, ME ;
Fotiadis, DI ;
Protopappas, VC ;
Mpozios, GV ;
Katsouras, CS ;
Kourtis, IC ;
Rees, MR ;
Michalis, LK .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (926) :122-129