ANGIOCARE: An automated system for fast three-dimensional coronary reconstruction by integrating angiographic and intracoronary ultrasound data

被引:38
作者
Bourantas, Christos V. [1 ,2 ]
Kalatzis, Fanis G. [3 ]
Papafaklis, Michail I. [2 ]
Fotiadis, Dimitrios I. [2 ,3 ]
Tweddel, Ann C. [1 ]
Kourtis, Iraklis C. [3 ]
Katsouras, Christos S. [3 ,4 ]
Michalis, Lampros K. [3 ,4 ]
机构
[1] Castle Hill Hosp, Dept Cardiol, Kingston Upon Hull HU16 5JQ, E Yorkshire, England
[2] Michailide Cardiol Ctr, GR-45110 Ioannina, Greece
[3] Univ Ioannina, Dept Comp Sci, Unit Med Technol & Intelligent Informat Syst, GR-45110 Ioannina, Greece
[4] Univ Ioannina, Sch Med, Dept Cardiol, GR-45110 Ioannina, Greece
关键词
three-dimensional reconstruction; intracoronary ultrasound; biplane angiography;
D O I
10.1002/ccd.21527
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The development of an automated, user-friendly system (ANGIOCARE), for rapid three-dimensional (3D) coronary reconstruction, integrating angiographic and, intracoronary ultrasound (ICUS) data. Methods: Biplane angiographic and ICUS sequence images are imported into the system where a prevalidated method is used for coronary reconstruction. This incorporates extraction of the catheter path from two end-diastolic X-ray images and detection of regions of interest (lumen, outer vessel wall) in the ICUS sequence by an automated border detection algorithm. The detected borders are placed perpendicular to the catheter path and established algorithms used to estimate their absolute orientation. The resulting 3D object is imported into an advanced visualization module with which the operator can interact, examine plaque distribution (depicted as a color coded map) and assess plaque burden by virtual endoscopy. Results: Data from 19 patients (27 vessels) undergoing biplane angiography and ICUS were examined. The reconstructed vessels were 21.3-80.2 mm long. The mean difference was 0.9 +/- 2.9% between the plaque volumes measured using linear 3D ICUS analysis and the volumes, estimated by taking into account the curvature of the vessel. The time required to reconstruct a luminal narrowing of 25 mm was approximately 10 min. Conclusion: The ANGIOCARE system provides rapid coronary reconstruction allowing the operator accurately to estimate the length of the lesion and determine plaque distribution and volume. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:166 / 175
页数:10
相关论文
共 26 条
[1]   A method for 3D reconstruction of coronary arteries using biplane angiography and intravascular ultrasound images [J].
Bourantas, CV ;
Kourtis, IC ;
Plissiti, ME ;
Fotiadis, DI ;
Katsouras, CS ;
Papafaklis, MI ;
Michalis, LK .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (08) :597-606
[2]   In vivo validation of a novel semi-automated method for border detection in intravascular ultrasound images [J].
Bourantas, CV ;
Plissiti, ME ;
Fotiadis, DI ;
Protopappas, VC ;
Mpozios, GV ;
Katsouras, CS ;
Kourtis, IC ;
Rees, MR ;
Michalis, LK .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (926) :122-129
[3]  
BOURANTAS CV, 2007, ESC C AUSTR VIENN SE
[4]   Accurate three-dimensional reconstruction of intravascular ultrasound data - Spatially correct three-dimensional reconstructions [J].
Evans, JL ;
Ng, KH ;
Wiet, SG ;
Vonesh, MJ ;
Burns, WB ;
Radvany, MG ;
Kane, BJ ;
Davidson, CJ ;
Roth, SI ;
Kramer, BL ;
Meyers, SN ;
McPherson, DD .
CIRCULATION, 1996, 93 (03) :567-576
[5]  
Friedman MH, 1996, ATHEROSCLEROSIS, V125, P183
[6]   Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries [J].
Gijsen, FJH ;
Oortman, RM ;
Wentzel, JJ ;
Schuurbiers, JCH ;
Tanabe, K ;
Degertekin, M ;
Ligthart, JM ;
Thury, A ;
de Feyter, PJ ;
Serruys, PW ;
Slager, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (11) :1325-1328
[7]  
HOSAKA M, 1992, MODELING CURVES SURF, P267
[8]   Advanced contour detection for three-dimensional intracoronary ultrasound: a validation - in vitro and in vivo [J].
Koning, G ;
Dijkstra, J ;
von Birgelen, C ;
Tuinenburg, JC ;
Brunette, J ;
Tardif, JC ;
Oemrawsingh, PW ;
Sieling, C ;
Melsa, S ;
Reiber, JHC .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (04) :235-248
[9]  
LABAN M, 1995, P COMP CARD 1995 VIE, P325
[10]   Towards quantitative analysis of coronary CTA [J].
Marquering, HA ;
Dijkstra, J ;
de Koning, PJH ;
Stoel, BC ;
Reiber, JHC .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01) :73-84