Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging

被引:26
作者
Aladl, UE
Hurwitz, GA
Dey, D
Levin, D
Drangova, M
Slomka, PJ [1 ]
机构
[1] Univ Western Ontario, Dept Diagnost Radiol & Nucl Med, London, ON, Canada
[2] Robarts Res Inst, London, ON N6A 5C1, Canada
[3] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
关键词
image registration; image segmentation; cardiac imaging; cardiac MRI; gated SPECT; coronary artery disease;
D O I
10.1002/jmri.20003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To develop an automatic registration method for electrocardiogram-gated myocardial perfusion single-photon emission computed tomography (SPECT) and cardiac cine-magnetic resonance imaging (RMI). Materials and Methods: Paired myocardial perfusion SPECT (MPS) and MRI from 20 patients were considered. MR images were presegmented by heart localization based on detection of cardiac motion and optimal thresholding. A registration algorithm based on mutual information was subsequently applied to all time frames or a selected subset form both modalities. Results: A preprocessing step significantly improved the accuracy of the registration when compared to automatic registration performed without preprocessing. Errors in translation parameters (T-x, T-y, T-z) averaged (1.0 +/- 1.5, 1.1 +/- 1.3, 0.9 +/- 0.9) pixels with MRI segmentation and (4.6 +/- 3.2, 3.4 +/- 2.6, 3.0 +/- 3.4) pixels without MRI segmentation. Errors in rotation parameters (R-x, R-y, R-z) averaged (5.4 +/- 2.9, 3.4 +/- 2.7, 4.5 +/- 3.6) degrees with MRI segmentation and (9.3 +/- 6.1, 4.8 +/- 4.3, 14.6 +/- 12.6) degrees without MRI segmentation. Error was calculated as the absolute difference between the expert manual and the automatic registration transformation. Conclusion: Automatic registration of gated MPS and cine MRI is possible with the use of a mutual information-based technique when MR images are presegmented. Cardiac motion can be used to isolate the left ventricle (LV) on the MR images automatically, and subsequently the segmented MR images can be coregistered with gated MPS.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 29 条
[1]
Achenbach S, 2000, Z KARDIOL, V89, P21
[2]
SEEDED REGION GROWING [J].
ADAMS, R ;
BISCHOF, L .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1994, 16 (06) :641-647
[3]
Dey D, 1999, J NUCL MED, V40, P448
[4]
SPATIAL AND TEMPORAL REGISTRATION OF CARDIAC SPECT AND MR-IMAGES - METHODS AND EVALUATION [J].
FABER, TL ;
MCCOLL, RW ;
OPPERMAN, RM ;
CORBETT, JR ;
PESHOCK, RM .
RADIOLOGY, 1991, 179 (03) :857-861
[5]
Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods [J].
Faber, TL ;
Vansant, JP ;
Pettigrew, RI ;
Galt, JR ;
Blais, M ;
Chatzimavroudis, G ;
Cooke, CD ;
Folks, RD ;
Waldrop, SM ;
Gurtler-Krawczynska, E ;
Wittry, MD ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) :645-651
[6]
GERMANO G, 1995, J NUCL MED, V36, P2138
[7]
Gilardi M C, 1996, Q J Nucl Med, V40, P142
[8]
Gilardi MC, 1998, COMPUT MED IMAG GRAP, V22, P391, DOI 10.1016/S0895-6111(98)00039-1
[9]
GROVA C, 2001, LECT NOTES COMPUTER, P275
[10]
Comparison of 201Tl, 99mTc-tetrofosmin, and dobutamine magnetic resonance imaging for identifying hibernating myocardium [J].
Gunning, MG ;
Anagnostopoulos, C ;
Knight, CJ ;
Pepper, J ;
Burman, ED ;
Davies, G ;
Fox, KM ;
Pennell, DJ ;
Ell, PJ ;
Underwood, SR .
CIRCULATION, 1998, 98 (18) :1869-1874