Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study

被引:104
作者
Galderisi, Maurizio [1 ]
Santoro, Alessandro [1 ]
Versiero, Marco [1 ]
Lomoriello, Vincenzo Schiano [1 ]
Esposito, Roberta [1 ]
Raia, Rosa [1 ]
Farina, Francesca [1 ]
Schiattarella, Pier Luigi [1 ]
Bonito, Manuela [1 ]
Olibet, Marinella [1 ]
de Simone, Giovanni [1 ]
机构
[1] Federico II Univ Hosp, Dept Clin & Expt Med, Naples, Italy
关键词
HAND-HELD ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; RECOMMENDATIONS;
D O I
10.1186/1476-7120-8-51
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Miniaturization has evolved in the creation of a pocket-size imaging device which can be utilized as an ultrasound stethoscope. This study assessed the additional diagnostic power of pocket size device by both experts operators and trainees in comparison with physical examination and its appropriateness of use in comparison with standard echo machine in a non-cardiologic population. Three hundred four consecutive non cardiologic outpatients underwent a sequential assessment including physical examination, pocket size imaging device and standard Doppler-echo exam. Pocket size device was used by both expert operators and trainees (who received specific training before the beginning of the study). All the operators were requested to give only visual, qualitative insights on specific issues. All standard Doppler-echo exams were performed by expert operators. One hundred two pocket size device exams were performed by experts and two hundred two by trainees. The time duration of the pocket size device exam was 304 +/- 117 sec. Diagnosis of cardiac abnormalities was made in 38.2% of cases by physical examination and in 69.7% of cases by physical examination + pocket size device (additional diagnostic power = 31.5%, p < 0.0001). The overall K between pocket size device and standard Doppler-echo was 0.67 in the pooled population (0.84 by experts and 0.58 by trainees). K was suboptimal for trainees in the eyeball evaluation of ejection fraction, left atrial dilation and right ventricular dilation. Overall sensitivity was 91% and specificity 76%. Sensitivity and specificity were lower in trainees than in experts. In conclusion, pocket size device showed a relevant additional diagnostic value in comparison with physical examination. Sensitivity and specificity were good in experts and suboptimal in trainees. Specificity was particularly influenced by the level of experience. Training programs are needed for pocket size device users.
引用
收藏
页数:7
相关论文
共 25 条
[1]   Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01) :1-25
[2]   Evaluation of ultrasound lung comets by hand-held echocardiography [J].
Bedetti G. ;
Gargani L. ;
Corbisiero A. ;
Frassi F. ;
Poggianti E. ;
Mottola G. .
Cardiovascular Ultrasound, 4 (1)
[3]  
DeCara J M, 2003, Eur J Echocardiogr, V4, P141, DOI 10.1053/euje.2002.0617
[4]  
GALDERISI M, 2008, G ITAL CARDIOL, V9, P1
[5]   Independent association of coronary flow reserve with left ventricular relaxation and filling pressure in arterial hypertension [J].
Galderisi, Maurizio ;
de Simone, Giovanni ;
D'Errico, Arcangelo ;
Sidiropulos, Milena ;
Viceconti, Roberto ;
Chinali, Marcello ;
Mondillo, Sergio ;
de Divitiis, Oreste .
AMERICAN JOURNAL OF HYPERTENSION, 2008, 21 (09) :1040-1046
[6]   Correlates of aortic root size in a population-based screening by hand-held echocardiography: "The Heart in the City" Study [J].
Galderisi, Maurizio ;
Ballo, Piercarlo ;
Innelli, Pasquale ;
Mondillo, Sergio .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 125 (01) :109-110
[7]   Hand-held echocardiography: Added value in clinical cardiological assessment [J].
Giannotti G. ;
Mondillo S. ;
Galderisi M. ;
Barbati R. ;
Zacà V. ;
Ballo P. ;
Agricola E. ;
Guerrini F. .
Cardiovascular Ultrasound, 3 (1)
[8]   Usefulness of a hand-hold ultrasound device for bedside examination of left ventricular function [J].
Kimura, BJ ;
Amundson, SA ;
Willis, CL ;
Gilpin, EA ;
DeMaria, AN .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (09) :1038-+
[9]   Accuracy and cost-effectiveness of single-view echocardiographic screening for suspected mitral valve prolapse [J].
Kimura, BJ ;
Scott, R ;
Willis, CL ;
DeMaria, AN .
AMERICAN JOURNAL OF MEDICINE, 2000, 108 (04) :331-333
[10]   European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease) [J].
Lancellotti, Patrizio ;
Moura, Luis ;
Pierard, Luc A. ;
Agricola, Eustachio ;
Popescu, Bogdan A. ;
Tribouilloy, Christophe ;
Hagendorff, Andreas ;
Monin, Jean-Luc ;
Badano, Luigi ;
Zamorano, Jose L. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (04) :307-332