Predicting walking METs and energy expenditure from speed or accelerometry

被引:68
作者
Brooks, AG
Gunn, SM
Withers, RT
Gore, CJ
Plummer, JL
机构
[1] Flinders Univ S Australia, Sch Educ, Exercise Physiol Lab, Adelaide, SA 5001, Australia
[2] Australian Inst Sport, Brooklyn Pk, SA, Australia
[3] Flinders Med Ctr, Brooklyn Pk, SA, Australia
关键词
CSA; MTI; velocity; self-paced;
D O I
10.1249/01.mss.0000170074.19649.0e
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: a) Compare the predictive potential of speed and CSAP (Computer Science Applications accelerometer positioned on the hip) for level terrain walking METs (1 MET = (V) over dot O-2 of 3.5 mL center dot kg(-1)center dot min(-1)) and energy expenditure (kcal center dot min(-1)); b) cross-validate previously published CSA(hip)- and speed-based MET and energy expenditure prediction equations; c) measure self-paced walking speed, exercise intensity (METs) and energy expenditure in the middle aged population. Methods: Seventy-two 35- to 45-yr-old volunteers walked around a level, paved quadrangle at what they perceived to be a moderate pace. Oxygen consumption was measured using the criterion Douglas bag technique. Speed, CSA(hip), heart rate, and Borg rating of perceived exertion were also monitored. Results: Speed explained 10% more variance of walking METs than CSA(hip). Speed and mass explained 8% more variance of walking energy expenditure (kcal center dot min(-1)) than CSA(hip) and mass. The best previously published regression equations predict our walking METs and energy expenditures within 95% prediction limits of +/- 0.7 METs (8) and +/- 1.0 kcal center dot min(-1) (23), respectively. Women paced themselves at a significantly higher mean speed (5.5 km center dot h(-1)) and intensity (4.1 METs) than their male counterparts (5.2 km center dot h(-1) and 3.8 METs). Both genders expended similar to 0.75 kcal center dot kg(-1) for every kilometer of level terrain walked. Conclusion: Speed-based MET and energy expenditure predictions during level terrain walking were more accurate than those utilizing CSA(hip).
引用
收藏
页码:1216 / 1223
页数:8
相关论文
共 35 条
[1]  
*AUSTR BUR STAT, 2001, AUSTR BUR STAT PUBL, P82
[2]  
Balogun J A, 1989, Int Disabil Stud, V11, P71
[3]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
Blessey R L, 1976, Phys Ther, V56, P1019
[6]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[7]   Measurement and prediction of METs during household activities in 35-to 45-year-old females [J].
Brooks, AG ;
Withers, RT ;
Gore, CJ ;
Vogler, AJ ;
Plummer, J ;
Cormack, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 91 (5-6) :638-648
[8]  
Bubb WJ, 1985, J CARDIOPULM REHABIL, V5, P462, DOI DOI 10.1097/00008483-198510210-00002
[9]   Sensitivity and reproducibility of accelerometry and heart rate in physical strain assessment during prosthetic gait [J].
Bussmann, JBJ ;
van den Berg-Emons, HJG ;
Angulo, SM ;
Stijnen, T ;
Stam, HJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 91 (01) :71-78
[10]   DETERMINANTS OF SELF-SELECTED WALKING PACE ACROSS AGES 19 TO 66 [J].
CUNNINGHAM, DA ;
RECHNITZER, PA ;
PEARCE, ME ;
DONNER, AP .
JOURNALS OF GERONTOLOGY, 1982, 37 (05) :560-564