Sensitivity and reproducibility of accelerometry and heart rate in physical strain assessment during prosthetic gait

被引:23
作者
Bussmann, JBJ
van den Berg-Emons, HJG
Angulo, SM
Stijnen, T
Stam, HJ
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Rehabil Med, NL-3000 CA Rotterdam, Netherlands
[2] Univ Med Ctr Rotterdam, Erasmus MC, Dept Biostat & Epidemiol, NL-3000 CA Rotterdam, Netherlands
关键词
accelerometry; amputation; heart rate reserve; walking;
D O I
10.1007/s00421-003-0916-1
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Accelerometry and heart rate (HR) are frequently used indicators of physical strain during normal daily life. The present study focused on the sensitivity and reproducibility of accelerometry (body motility, the intensity of body movement measured with accelerometry) and HR (percentage maximal heart rate reserve, %HRRmax) in the assessment of physical strain during walking in persons with a lower leg amputation, using persons without an amputation as reference. Ten patients with an amputation of the leg and ten comparison subjects performed, at an interval of 1 month, the same walking protocol three times. Subjects walked at a preferred speed and at fixed speeds. At their preferred walking speed, speed (0.63 vs 1.31 m s(-1), P=0.001), body motility [0.53 vs 0.91 (arbitrary unit), P=0.001] and %HRRmax (42.5 vs 27.6, P=0.02) differed between the amputation group and the comparison group. At fixed walking speeds, only %HRRmax differed between groups (Pless than or equal to0.002) and showed a session effect (P=0.02). The relationship between body motility and %HRRmax in the patient group was significantly different from that in the comparison group. It can be concluded that accelerometry is strongly related with walking speed, but not sensitive to differences and changes in economy, contrary to %HRRmax. The use of accelerometry as an indicator of the level of physical strain in persons with an amputation is not feasible. The added value of a calibration procedure has to be studied.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 35 条
[1]  
ASTRAND PO, 1987, TXB WORK PHYSL PHYSL, P188
[2]  
BOONSTRA AM, 1994, SCAND J REHABIL MED, V26, P217
[3]  
BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
[4]   Validity and reliability of measurements obtained with an "activity monitor" in people with and without a transtibial amputation [J].
Bussmann, HBJ ;
Reuvekamp, PJ ;
Veltink, PH ;
Martens, WLJ ;
Stam, HJ .
PHYSICAL THERAPY, 1998, 78 (09) :989-998
[5]  
Bussmann JBJ, 2000, MED SCI SPORT EXER, V32, P1462
[6]   Quantification of physical activities by means of ambulatory accelerometry: A validation study [J].
Bussmann, JBJ ;
Tulen, JHM ;
van Herel, ECG ;
Stam, HJ .
PSYCHOPHYSIOLOGY, 1998, 35 (05) :488-496
[7]   Ambulatory accelerometry to quantify motor behaviour in patients after failed back surgery: a validation study [J].
Bussmann, JBJ ;
van de Laar, YM ;
Neeleman, MP ;
Stam, HJ .
PAIN, 1998, 74 (2-3) :153-161
[8]   Measuring daily behavior using ambulatory accelerometry: The activity monitor [J].
Bussmann, JBJ ;
Martens, WLJ ;
Tulen, JHM ;
Schasfoort, FC ;
van den Berg-Emons, HJG ;
Stam, HJ .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 2001, 33 (03) :349-356
[9]   MOBILITY AFTER LOWER-LIMB AMPUTATION [J].
COLLIN, C ;
COLLIN, J .
BRITISH JOURNAL OF SURGERY, 1995, 82 (08) :1010-1011
[10]   Physical capacity and physical strain in persons with tetraplegia; The role of sport activity [J].
Dallmeijer, AJ ;
Hopman, MTE ;
vanAs, HHJ ;
vanderWoude, LHV .
SPINAL CORD, 1996, 34 (12) :729-735