Measuring daily behavior using ambulatory accelerometry: The activity monitor

被引:231
作者
Bussmann, JBJ
Martens, WLJ
Tulen, JHM
Schasfoort, FC
van den Berg-Emons, HJG
Stam, HJ
机构
[1] Univ Rotterdam Hosp, Dept Rehabil, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Rotterdam, Netherlands
[3] PhyVis, Gemert, Netherlands
[4] Erasmus Univ, Rotterdam, Netherlands
来源
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS | 2001年 / 33卷 / 03期
关键词
D O I
10.3758/BF03195388
中图分类号
B841 [心理学研究方法];
学科分类号
040201 ;
摘要
Advanced ambulatory systems that measure aspects of overt human behavior during normal daily life have become feasible, owing to developments in data recording and sensor technology. One such instrument is the Activity Monitor (AM). This paper provides a technical description of the AM and information about its validity and current applications. The AM is based on ambulatory accelerometry, the aim of which is to assess postures and motions for long-term (> 24-h) measurement periods during normal daily life. Accelerometers are attached to the thighs, trunk, and lower arms, and signals are continuously stored in a digital portable recorder. In the postmeasurement analysis, postures and motions are detected by means of custom-made software programs. Validity studies performed on different populations showed high agreement scores between the computerized and automatic AM output and the visually analyzed video recordings. The AM has so far been applied in rehabilitation, psychophysiology, and cardiology but has many possibilities in behavioral research.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 32 条
  • [1] A SIMPLE ACTIVITY MEASURE FOR USE WITH AMBULATORY SUBJECTS
    ANASTASIADES, P
    JOHNSTON, DW
    [J]. PSYCHOPHYSIOLOGY, 1990, 27 (01) : 87 - 93
  • [2] [Anonymous], AMBULATORY ASSESSMEN
  • [3] Ambulatory monitoring of children's activity
    Busser, HJ
    Ott, J
    vanLummel, RC
    Uiterwaal, M
    Blank, R
    [J]. MEDICAL ENGINEERING & PHYSICS, 1997, 19 (05) : 440 - 445
  • [4] Validity and reliability of measurements obtained with an "activity monitor" in people with and without a transtibial amputation
    Bussmann, HBJ
    Reuvekamp, PJ
    Veltink, PH
    Martens, WLJ
    Stam, HJ
    [J]. PHYSICAL THERAPY, 1998, 78 (09): : 989 - 998
  • [5] Bussmann J. B. J., 1998, AMBULATORY MONITORIN
  • [6] Bussmann JBJ, 2000, MED SCI SPORT EXER, V32, P1462
  • [7] Quantification of physical activities by means of ambulatory accelerometry: A validation study
    Bussmann, JBJ
    Tulen, JHM
    van Herel, ECG
    Stam, HJ
    [J]. PSYCHOPHYSIOLOGY, 1998, 35 (05) : 488 - 496
  • [8] Ambulatory accelerometry to quantify motor behaviour in patients after failed back surgery: a validation study
    Bussmann, JBJ
    van de Laar, YM
    Neeleman, MP
    Stam, HJ
    [J]. PAIN, 1998, 74 (2-3) : 153 - 161
  • [9] Analysis and decomposition of signals obtained by thigh-fixed uni-axial accelerometry during normal walking
    Bussmann J.B.J.
    Damen L.
    Stam H.J.
    [J]. Medical and Biological Engineering and Computing, 2000, 38 (6) : 632 - 638
  • [10] Techniques for measurement and assessment of mobility in rehabilitation: a theoretical approach
    Bussmann, JBJ
    Stam, HJ
    [J]. CLINICAL REHABILITATION, 1998, 12 (06) : 455 - 464