Characteristics of bremsstrahlung in electron beams

被引:31
作者
Zhu, TC [1 ]
Das, IJ [1 ]
Bjärngard, BE [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
关键词
bremsstrahlung; electron beam; radiotherapy; Monte Carlo;
D O I
10.1118/1.1382608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Clinical electron beams contain an admixture of bremsstrahlung produced in structures in the accelerator head, in field-defining cerrobend or lead cutouts, and in the irradiated patient or water phantom. Accurate knowledge of these components is important for dose calculations and treatment planning. In this study, the bremsstrahlung components are separated for electron beams (energy 6-22 MeV, diameter 0-5 cm) using measurements in water and calculations. The results show that bremsstrahlung from the accelerator head dominates and increases with field size for electron beams generated by accelerators equipped with scattering foils. The bremsstrahlung from the field-defining cerrobend accounts for 10% to 30% of the total bremsstrahlung and decreases with increasing beam radius. The bremsstrahlung is softer than the x-ray beams of corresponding nominal energy since the latter are hardened by the flattening filter. For the 6, 12, and 22 MeV electron beams, the effective attenuation coefficients in water for the bremsstrahlung are 0.058, 0.050, and 0.043 cm(-1). The depths of maximum dose at 100 cm SSD are 0.8, 1.7, and 3.0 cm. The position of the virtual source of the bremsstrahlung shifts downstream from the nominal source position by 20, 13, 5.6 cm, respectively. The lateral bremsstrahlung dose distribution is more forward-peaked for higher electron energy. The bremsstrahlung components could be described for any machine by a set of simple measurements and can be modeled by an analytical expression. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1352 / 1358
页数:7
相关论文
共 25 条
[1]   COLLIMATOR SCATTER IN PHOTON THERAPY BEAMS [J].
AHNESJO, A .
MEDICAL PHYSICS, 1995, 22 (03) :267-278
[2]   ANALYTIC MODELING OF PHOTON SCATTER FROM FLATTENING FILTERS IN PHOTON THERAPY BEAMS [J].
AHNESJO, A .
MEDICAL PHYSICS, 1994, 21 (08) :1227-1235
[3]  
ALTSHULER DM, 1991, DEV VISUAL SYSTEM, V3, P37
[4]  
[Anonymous], [No title captured]
[5]  
BERGER MJ, 1978, INFLUENCE SCATTERING
[6]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[7]  
BJARNGARD B E, 1976, Medical Physics (Woodbury), V3, P153, DOI 10.1118/1.594281
[8]   Test procedures for verification of an electron pencil beam algorithm implemented for treatment planning [J].
Blomquist, M ;
Karlsson, M ;
Karlsson, M .
RADIOTHERAPY AND ONCOLOGY, 1996, 39 (03) :271-286
[9]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[10]   RADIATION BEAM CHARACTERISTICS OF A 22 MEV MICROTRON [J].
BRAHME, A ;
SVENSSON, H .
ACTA RADIOLOGICA ONCOLOGY, 1979, 18 (03) :244-272