Contrast-enhanced MR imaging of coronary arteries: Comparison of intra- and extravascular contrast agents in swine

被引:60
作者
Li, DB
Zheng, J
Weinmann, HJ
机构
[1] Northwestern Univ, Sch Med, Dept Radiol, Chicago, IL 60611 USA
[2] Schering AG, D-1000 Berlin, Germany
关键词
animals; coronary vessels MR; magnetic resonance (MR); contrast enhancement; vascular studies;
D O I
10.1148/radiology.218.3.r01mr03670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the efficacy of an intravascular contrast agent, gadomer-17, in improving magnetic resonance (MR) imaging of coronary arteries with that of an extravascular agent, gadopentetate dimeglumine, in pigs. MATERIALS AND METHODS: Eight pigs underwent imaging after three injections: 0.20 mmol of gadopentetate dimeglumine per kilogram of body weight and 0.05 and 0.10 mmol/kg gadomer-17. Coronary images were acquired repeatedly after each injection by using an inversion-recovery-prepared segmented three-dimensional sequence with either breath holding (n = 4) or respiratory gating (n = 4). Coronary artery-to-myocardium contrast-to-noise ratios (CNRs) were compared between injections. RESULTS: At breath-hold imaging, substantial CNR improvement over precontrast images was observed in images acquired during the first pass of gadopentetate dimeglumine in coronary arteries and up to 6 and 10 minutes after 0.05 and 0.10 mmol/kg of gadomer-17 injections, respectively. The CNR with 0.10 mmol/kg of gadomer-17 was 20% (P < .05) higher than that with gadopentetate dimeglumine at first-pass imaging. At respiratory-gated imaging, significant CNR improvement (P < .05) over precontrast images was observed in images acquired up to 10, 30, and 50 minutes after gadopentetate dimeglumine and both gadomer-17 injections, respectively. The CNR on the first images obtained after 0.10 mmol/kg gadomer-17 injection was 168% (P < .05) higher than that on the images obtained after gadopentetate dimeglumine injection. CONCLUSION: Gadomer-17 provided greater and more persistent CNR improvements than did gadopentetate dimeglumine; further evaluation of its utility for coronary imaging in humans is warranted.
引用
收藏
页码:670 / 678
页数:9
相关论文
共 33 条
[1]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[2]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[3]   Contrast-enhanced 3D-TOF MRA of peripheral vessels: Intravascular versus extracellular MR contrast media [J].
Engelbrecht, MR ;
Saeed, M ;
Wendland, MF ;
Canet, E ;
Oksendal, AN ;
Higgins, CB .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :616-621
[4]   Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography [J].
Goldfarb, JW ;
Edelman, RR .
RADIOLOGY, 1998, 206 (03) :830-834
[5]   Steady-state and dynamic MR angiography with MS-325: Initial experience in humans [J].
Grist, TM ;
Korosec, FR ;
Peters, DC ;
Witte, S ;
Walovitch, RC ;
Dolan, RP ;
Bridson, WE ;
Yucel, EK ;
Mistretta, CA .
RADIOLOGY, 1998, 207 (02) :539-544
[6]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[7]  
Hofman MBM, 1999, MAGN RESON MED, V41, P360, DOI 10.1002/(SICI)1522-2594(199902)41:2<360::AID-MRM21>3.0.CO
[8]  
2-C
[9]  
Johansson LO, 1999, J MAGN RESON IMAGING, V9, P552, DOI 10.1002/(SICI)1522-2586(199904)9:4<552::AID-JMRI7>3.0.CO
[10]  
2-5