Contrast-enhanced 3D-TOF MRA of peripheral vessels: Intravascular versus extracellular MR contrast media

被引:44
作者
Engelbrecht, MR [1 ]
Saeed, M [1 ]
Wendland, MF [1 ]
Canet, E [1 ]
Oksendal, AN [1 ]
Higgins, CB [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1998年 / 8卷 / 03期
关键词
3D MR angiography; ultrasmall superparamagnetic iron oxide particles MR contrast media; peripheral vessels;
D O I
10.1002/jmri.1880080315
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR contrast media have been used to improve MR angiography (MRA). Their effect has been particularly beneficial for extracranial MRA. This study evaluated the efficacy of a new formulation of ultrasmall superparamagnetic iron oxide particles (USPIO) on three-dimensional (3D) time of night (TOF) MRA in the pelvis and lower limb circulation. Each of six dogs received 3 mg/kg of USPIO and .2 mmol/kg of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) bis-methylamide (BMA) by intravenous infusion on separate examinations. Precontrast and postcontrast 3D-TOF MRA images of the lower extremities were acquired over the course of 45 minutes postinjection. Signal intensity (SI) was measured on axial views along the external iliac, femoral, and popliteal arteries, USPIO provided clear demarcation of the major primary, secondary, and tertiary vessels and the improved contrast-to-noise ratio (CNR) was maintained for 45 minutes. Gd-DTPA-BMA provided less signal enhancement than USPIO. The increase in CNR with this agent had significantly declined by 15 minutes after injection. The major vessels could no longer be visualized at 30 and 45 minutes after injection of Gd-DTPA-BMA. This study demonstrates the efficacy of USPIO as a contrast medium for 3D-TOF MRA. It was concluded that USPIO provided effective and persistent enhancement of the peripheral vessels.
引用
收藏
页码:616 / 621
页数:6
相关论文
共 18 条
  • [1] IMMUNOGENICITY OF GADOLINIUM-BASED CONTRAST AGENTS FOR MAGNETIC-RESONANCE-IMAGING - INDUCTION AND CHARACTERIZATION OF ANTIBODIES IN ANIMALS
    BAXTER, AB
    MELNIKOFF, S
    STITES, DP
    BRASCH, RC
    [J]. INVESTIGATIVE RADIOLOGY, 1991, 26 (12) : 1035 - 1040
  • [2] Evaluation of the effects of intravascular MR contrast media (gadolinium dendrimer) on 3D time of flight magnetic resonance angiography of the body
    Bourne, MW
    Margerun, L
    Hylton, N
    Campion, B
    Lai, JJ
    Derugin, N
    Higgins, CB
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (02): : 305 - 310
  • [3] CACHERIS WP, 1990, MAGN RESON IMAGING, V8, P476
  • [4] SUPERPARAMAGNETIC IRON-OXIDES AS POSITIVE MR CONTRAST AGENTS - INVITRO AND INVIVO EVIDENCE
    CHAMBON, C
    CLEMENT, O
    LEBLANCHE, A
    SCHOUMANCLAEYS, E
    FRIJA, G
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (04) : 509 - 519
  • [5] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [6] MR-ANGIOGRAPHY - PRESENT AND FUTURE
    EDELMAN, RR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) : 1 - 11
  • [7] ENHANCEMENT OF MR-ANGIOGRAPHY WITH IRON-OXIDE - PRELIMINARY STUDIES IN WHOLE-BLOOD PHANTOM AND IN ANIMALS
    FRANK, H
    WEISSLEDER, R
    BRADY, TJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 209 - 213
  • [8] ABDOMINAL-AORTA AND RENAL-ARTERY STENOSIS - EVALUATION WITH MR ANGIOGRAPHY
    KIM, D
    EDELMAN, RR
    KENT, KC
    PORTER, DH
    SKILLMAN, JJ
    [J]. RADIOLOGY, 1990, 174 (03) : 727 - 731
  • [9] EXPERIMENTAL GD-DTPA POLYLYSINE ENHANCED MR ANGIOGRAPHY - SEQUENCE OPTIMIZATION
    MARCHAL, G
    BOSMANS, H
    VANHECKE, P
    JIANG, YB
    AERTS, P
    BAUER, H
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) : 711 - 715
  • [10] MR ANGIOGRAPHY WITH GADOPENTETATE DIMEGLUMINE POLYLYSINE - EVALUATION IN RABBITS
    MARCHAL, G
    BOSMANS, H
    VANHECKE, P
    SPECK, U
    AERTS, P
    VANHOENACKER, P
    BAERT, AL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (02) : 407 - 411