Determination of zinc in plant samples by isotope dilution inductively coupled plasma mass spectrometry

被引:16
作者
Mestek, O [1 ]
Komínková, J [1 ]
Koplík, R [1 ]
Suchánek, M [1 ]
机构
[1] Inst Chem Technol, Prague 16626 6, Czech Republic
关键词
zinc; isotope dilution; mass spectrometry; uncertainty;
D O I
10.1016/S0039-9140(01)00361-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Determination of zinc involved spiking with Zn-68 enriched solution, digestion by HNO3 + H2O2 in microwave decomposition unit, off-line separation of zinc on Chelex-100 column and measurement of (Zn-64 + Zn-66)/Zn-68 isotope ratio on ICP-MS spectrometer with a quadrupole mass filter. After optimization of standard operation procedure (details are given) the method was validated. LOD was found to be 0.3 mug g(-1) for the procedure without zinc separation and 3.6 mug g(-1) for the procedure involving zinc separation, respectively. The accuracy of results was proved by analyses of several CRM and a primary solution of zinc, the concentration of which was verified by gravimetry and complexometric titration. Barium is the only element causing serious interferences and it must be removed from samples. The uncertainty budget is given together with the scheme of combined uncertainty calculation. The main uncertainty components are contamination during zinc separation and uncertainty of isotopic composition of natural zinc. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:927 / 934
页数:8
相关论文
共 16 条
[1]   ISOTOPE-DILUTION MASS-SPECTROMETRY OF MICROELECTRONICALLY RELEVANT HEAVY-METAL TRACES IN HIGH-PURITY COBALT [J].
BEER, B ;
HEUMANN, KG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (8-9) :351-355
[2]   Determination of trace amounts of zinc in water samples by flow injection isotope dilution inductively coupled plasma mass spectrometry [J].
Hwang, TJ ;
Jiang, SJ .
ANALYST, 1997, 122 (03) :233-237
[3]   Determination of trace impurities on silicon-wafer surface by isotope dilution analysis using electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Komoda, M ;
Chiba, K ;
Uchida, H .
ANALYTICAL SCIENCES, 1996, 12 (01) :21-25
[4]  
MASSART DL, 1998, CHEMOMETRICS TXB, P101
[5]   Computer simulation of the uncertainty of analytical results [J].
Mestek, O ;
Suchánek, M ;
Koplík, R ;
Fingerová, H ;
Curdová, E .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (03) :203-207
[6]  
Mestek O, 2000, CHEM LISTY, V94, P136
[7]   Accurate determination of iron, copper and zinc in human serum by isotope dilution analysis using double focusing ICP-MS [J].
Muñiz, CS ;
Gayón, JMM ;
Alonso, JIG ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1505-1510
[8]  
OHNESORGE F K, 1991, METALS THEIR COMPOUN, P1309
[9]   DETERMINATION OF TRACE IMPURITIES IN PURE COPPER BY ISOTOPE-DILUTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
PARK, CJ ;
PARK, SR ;
YANG, SR ;
HAN, MS ;
LEE, KW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :641-645
[10]   Isotopic compositions of the elements 1997 [J].
Rosman, KJR ;
Taylor, PDP .
PURE AND APPLIED CHEMISTRY, 1998, 70 (01) :217-235