Accurate determination of iron, copper and zinc in human serum by isotope dilution analysis using double focusing ICP-MS

被引:45
作者
Muñiz, CS [1 ]
Gayón, JMM [1 ]
Alonso, JIG [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
D O I
10.1039/a901751h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of an ICP-MS method for the determination of three essential trace elements, Fe, Cu and Zn, in human serum by isotope dilution analysis is described. A double focusing ICP mass spectrometer (ELEMENT) working at a nominal resolution of 3000 allowed the complete resolution of polyatomic ions overlapping the main isotopes of these elements. The isotope ratios measured for the determination of Fe, Cu and Zn were Fe-57/Fe-56, Cu-65/Cu-63 and Zn-67/Zn-64, respectively. Instrumental parameters of the mass spectrometer were optimised for optimum precision, while keeping the total time of analysis under 6 min (2 min per element). The RSD values obtained for the isotope ratios of Fe (57/56), Cu (65/63) and Zn (67/64) were 0.7, 0.2 and 0.8%, respectively, for a natural standard aqueous solution of 50 mu g l(-1). The measured isotope ratios were corrected for dead time on the detector and mass discrimination errors. The sample to spike ratio was optimised to minimise the relative error on the isotope ratio measurement. Serum samples were diluted 1+19 with ultrapure water after the addition of the Fe-57, Cu-65 and Zn-67 spikes. The proposed method was validated by the analysis of NIST SRM 1598 Inorganic Constituents in Bovine Serum, the levels found being in agreement with the certified values. Finally, the method was applied to the analysis of 21 serum samples from healthy blood donors.
引用
收藏
页码:1505 / 1510
页数:6
相关论文
共 31 条
[1]   DETERMINATION OF FISSION-PRODUCTS AND ACTINIDES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY USING ISOTOPE-DILUTION ANALYSIS - A STUDY OF RANDOM AND SYSTEMATIC-ERRORS [J].
ALONSO, JIG .
ANALYTICA CHIMICA ACTA, 1995, 312 (01) :57-78
[2]  
Barnes RM, 1996, FRESEN J ANAL CHEM, V355, P433
[3]   Semiquantitative elemental analysis of water samples using double focusing inductively coupled plasma mass spectrometry [J].
Bayon, MM ;
Alonso, JIG ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :1027-1032
[4]   THE ASSESSMENT OF REFERENCE VALUES FOR ELEMENTS IN HUMAN BIOLOGICAL TISSUES AND FLUIDS - A SYSTEMATIC REVIEW [J].
CAROLI, S ;
ALIMONTI, A ;
CONI, E ;
PETRUCCI, F ;
SENOFONTE, O ;
VIOLANTE, N .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1994, 24 (5-6) :363-398
[5]   Sample collection guidelines for trace elements in blood and urine [J].
Cornelis, R ;
Heinzow, B ;
Herber, RFM ;
Christensen, JM ;
Poulsen, OM ;
Sabbioni, E ;
Templeton, DM ;
Thomassen, Y ;
Vahter, M ;
Vesterberg, O .
JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 1996, 10 (02) :103-127
[6]   MASS-SPECTROMETRIC METHODS FOR STUDYING NUTRIENT MINERAL AND TRACE-ELEMENT ABSORPTION AND METABOLISM IN HUMANS USING STABLE ISOTOPES - A REVIEW [J].
CREWS, HM ;
DUCROS, V ;
EAGLES, J ;
MELLON, FA ;
KASTENMAYER, P ;
LUTEN, JB ;
MCGAW, BA .
ANALYST, 1994, 119 (11) :2491-2514
[7]  
DEWANNEMACKER G, 1999, 1999 EUR WINT C PLAS
[8]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[9]   ISOTOPIC AND NUCLEAR ANALYTICAL TECHNIQUES IN BIOLOGICAL-SYSTEMS - A CRITICAL-STUDY .10. ELEMENTAL ISOTOPE-DILUTION ANALYSIS WITH RADIOACTIVE AND STABLE ISOTOPES [J].
FASSETT, JD .
PURE AND APPLIED CHEMISTRY, 1995, 67 (11) :1943-1949
[10]  
Frieden E., 1984, BIOCH ESSENTIAL ULTR, P6