Determination of ventilatory liver movement via radiographic evaluation of diaphragm position

被引:106
作者
Balter, JM
Dawson, LA
Kazanjian, S
McGinn, C
Brock, KK
Lawrence, T
Ten Haken, R
机构
[1] Univ Michigan Hlth Syst, Dept Radiat Oncol, Ann Arbor, MI USA
[2] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 51卷 / 01期
关键词
radiotherapy; organ movement; breathing; ventilation;
D O I
10.1016/S0360-3016(01)01649-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the accuracy of estimation of liver movement inferred by observing diaphragm excursion on radiographic images. Methods and Materials: Eight patients with focal liver cancer had platinum embolization microcoils implanted in their livers during catheterization of the hepatic artery for delivery of regional chemotherapy. These patients underwent fluoroscopy, during which normal breathing movement was recorded on videotape. Movies of breathing movement were digitized, and the relative projected positions of the diaphragm and coils were recorded. For 6 patients, daily radiographs were also acquired during treatment. Retrospective measurements of coil position were taken after the diaphragm was aligned with the superior portion of the liver on digitally reconstructed radiographs. Results: Coil movement of 4.9 to 30.4 mm was observed during normal breathing. Diaphragm position tracked inferior-superior coil displacement accurately (population sigma 1.04 mm) throughout the breathing cycle. The range of coil movement was predicted by the range of diaphragm movement with an accuracy of 2.09 mm (sigma). The maximum error observed measuring coil movement using diaphragm position was 3.8 mm for a coil 9.8 cm inferior to the diaphragm. However, the distance of the coil from the top of the diaphragm did not correlate significantly with the error in predicting liver excursion. Analysis of daily radiographs showed that the error in predicting coil position using the diaphragm as an alignment landmark was 1.8 mm (sigma) in the inferior-superior direction and 2.2 min in the left-right direction, similar in magnitude to the inherent uncertainty in alignment. Conclusions: This study demonstrated that the range of ventilatory movement of different locations within the liver is predicted by diaphragm position to an accuracy that matches or exceeds existing systems for ventilatory tracking. This suggests that the diaphragm is an acceptable anatomic landmark for radiographic estimation of liver movement in anterior-posterior projections for most patients. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:267 / 270
页数:4
相关论文
共 13 条
  • [1] BALTER J, 1996, TELETHERAPY PRESENT, P471
  • [2] Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging
    Balter, JM
    Lam, KL
    McGinn, CJ
    Lawrence, TS
    Ten Haken, RK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04): : 939 - 943
  • [3] Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing
    Balter, JM
    TenHaken, RK
    Lawrence, TS
    Lam, KL
    Robertson, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01): : 167 - 174
  • [4] Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility
    Balter, JM
    Lam, KL
    Sandler, HM
    Littles, JF
    Bree, RL
    TenHaken, RK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1281 - 1286
  • [5] Respiration gated radiotherapy treatment: A technical study
    Kubo, HD
    Hill, BC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) : 83 - 91
  • [6] Lawrence T S, 1993, Oncology (Williston Park), V7, P51
  • [7] LAWRENCE TS, 1993, ONCOLOGY, V63, P57
  • [8] A method for incorporating organ motion due to breathing into 3D dose calculations
    Lujan, AE
    Larsen, EW
    Balter, JM
    Ten Haken, RK
    [J]. MEDICAL PHYSICS, 1999, 26 (05) : 715 - 720
  • [9] Constitutive modelling of abdominal organs
    Miller, K
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (03) : 367 - 373
  • [10] MURPHY M, 2000, IN PRESS COMPUTER AI