Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility

被引:153
作者
Balter, JM [1 ]
Lam, KL [1 ]
Sandler, HM [1 ]
Littles, JF [1 ]
Bree, RL [1 ]
TenHaken, RK [1 ]
机构
[1] UNIV MICHIGAN,MED CTR,DEPT RADIOL,ANN ARBOR,MI 48109
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 05期
关键词
prostate movement; conformal therapy; portal imaging;
D O I
10.1016/0360-3016(95)02083-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: Prostate movement is a major consideration in the formation of target volumes for conformal radiation therapy of prostate cancer. The goal of this study was to determine the technical feasibility of using implanted radiopaque markers and digital imaging to localize the prostate at the time of treatment, thus allowing for reduction of the margin required for uncertainty in target position. Methods and Materials: Radiopaque markers implanted around the prostate prior to treatment are visible on electronic radiographs generated with a portal imager or diagnostic imaging device. The locations of the images of these markers on the digital radiographs were automatically determined by a template-matching algorithm. The coordinates of the markers were found by projecting rays through the marker locations on orthogonal radiographs using a three-dimensional (3D) point-matching algorithm. Prostate and/or patient movement was inferred from the marker displacements. Images generated from known movements of a phantom with implanted markers were tested with this algorithm. Locations of markers from daily images of patients with implanted markers were determined by both manual and automatic techniques to determine the efficacy of automated localization on typical clinical images. Results: Prostate movements can be automatically detected in a phantom using low-energy photons within 30 s after image acquisition and with a precision of better than 1 mm in translation and 1 degrees in rotation (indistinguishable from the uncertainty in measuring precision). Conclusion: The studies show that on-line repositioning of the patient based on localization of the markers at the time of treatment is feasible, and may reduce the uncertainty in prostate location when combined with practical on-line repositioning techniques.
引用
收藏
页码:1281 / 1286
页数:6
相关论文
共 19 条
[1]
THIN-FILM, FLAT-PANEL, COMPOSITE IMAGERS FOR PROJECTION AND TOMOGRAPHIC IMAGING [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
LAM, KL ;
MORTON, EJ ;
TENHAKEN, RK ;
YORKSTON, J ;
CLINTHORNE, NH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (03) :482-490
[2]
BALTER J, IN PRESS INT J RAD O
[3]
ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS [J].
BALTER, JM ;
CHEN, GTY ;
PELIZZARI, CA ;
KRISHNASAMY, S ;
RUBIN, S ;
VIJAYAKUMAR, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01) :137-143
[4]
CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[5]
BALTER JM, 1993, MED PHYS, V20, P922
[6]
ANALYSIS OF PROSTATE AND SEMINAL-VESICLE MOTION [J].
BEARD, CJ ;
BUSSIERE, MR ;
PLUNKETT, ME ;
COLEMAN, CN ;
KIJEWSKI, PK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 :136-136
[7]
FRAASS BA, UNPUB INT J RAD ONCO
[8]
IMPROVEMENT OF PRECISION IN SPATIAL LOCALIZATION OF RADIO-OPAQUE MARKERS USING THE 2-FILM TECHNIQUE [J].
LAM, KL ;
TENHAKEN, RK .
MEDICAL PHYSICS, 1991, 18 (06) :1126-1131
[9]
AUTOMATED-DETERMINATION OF PATIENT SETUP ERRORS IN RADIATION-THERAPY USING SPHERICAL RADIO-OPAQUE MARKERS [J].
LAM, KL ;
TENHAKEN, RK ;
MCSHAN, DL ;
THORNTON, AF .
MEDICAL PHYSICS, 1993, 20 (04) :1145-1152
[10]
Marsh L H, 1992, Med Dosim, V17, P123