Localization of CO2 source by a hexapod robot equipped with an anemoscope and a gas sensor

被引:32
作者
Iida, Michihisa [1 ]
Kang, Donhyeon [1 ]
Taniwaki, Mitsuru [1 ]
Tanaka, Mutsumi [1 ]
Umeda, Mikio [1 ]
机构
[1] Kyoto Univ, Grad Sch Agr, Lab Field Robot, Div Environm Sci & Technol,Sakyo Ku, Kyoto 6068502, Japan
关键词
biological robot; precision agriculture; field data collection; odor source localization;
D O I
10.1016/j.compag.2008.01.016
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A hexapod robot was developed to explore an agricultural field and gather agronomical information such as soil nutrients and plant growth. in addition, a sensor device for the robot to track a gas source was developed. The sensor device consisted of a CO2 gas sensor and an anemoscope. The gas sensor detected the concentration Of CO2 in the surroundings, and the anemoscope indicated the upwind direction from the robot. An indoor test was conducted during which the hexapod robot tracked windward direction using the sensor device. According to the results, the hexapod robot with the sensor device successfully localized a CO2 source that was in the upwind direction. The robot paused on the spot under windless conditions, and walked windward as soon as the wind started blowing again. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 20 条
[1]   Fast and robust: Hexapedal robots via shape deposition manufacturing [J].
Cham, JG ;
Bailey, SA ;
Clark, JE ;
Full, RJ ;
Cutkosky, MR .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2002, 21 (10-11) :869-882
[2]   Architectures for a biomimetic hexapod robot [J].
Delcomyn, F ;
Nelson, ME .
ROBOTICS AND AUTONOMOUS SYSTEMS, 2000, 30 (1-2) :5-15
[3]  
DOHI M, 2002, P AUT TECHN OFF ROAD, P196
[4]  
DOHI M, 2000, BIOR 2 IFAC CIGR INT, V2, P91
[5]  
Iida M., 2006, Journal of the Japanese Society of Agricultural Machinery, V68, P138
[6]   Controlling a gas/odor plume-tracking robot based on transient responses of gas sensors [J].
Ishida, H ;
Nakayama, G ;
Nakamoto, T ;
Moriizumi, T .
IEEE SENSORS JOURNAL, 2005, 5 (03) :537-545
[7]   Odor-source localization in the clean room by an autonomous mobile sensing system [J].
Ishida, H ;
Kagawa, Y ;
Nakamoto, T ;
Moriizumi, T .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :115-121
[8]   STUDY OF AUTONOMOUS MOBILE SENSING SYSTEM FOR LOCALIZATION OF ODOR SOURCE USING GAS SENSORS AND ANEMOMETRIC SENSORS [J].
ISHIDA, H ;
SUETSUGU, K ;
NAKAMOTO, T ;
MORIIZUMI, T .
SENSORS AND ACTUATORS A-PHYSICAL, 1994, 45 (02) :153-157
[9]  
ISHIDA H, 1996, SENSOR ACTUAT A-PHYS, V99, P225
[10]  
KANG DH, 2006, 3 IFAC INT WORKSH BI, P271