Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee

被引:642
作者
Ezzell, GA
Galvin, JM
Low, D
Palta, JR
Rosen, I
Sharpe, MB
Xia, P
Xiao, Y
Xing, L
Yu, CX
机构
[1] Mayo Clin, Scottsdale, AZ 85259 USA
[2] Thomas Jefferson Univ Hosp, Philadelphia, PA 19019 USA
[3] Mallinckrodt Inst Radiol, St Louis, MO 63101 USA
[4] Univ Florida, Gainesville, FL 32610 USA
[5] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77001 USA
[6] Princess Margaret Hosp, Toronto, ON M5G 2M9, Canada
[7] Univ Calif San Francisco, San Francisco, CA 94101 USA
[8] Stanford Univ, Sch Med, Stanford, CA 94305 USA
[9] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
3-D conformal radiotherapy; intensity-modulated radiation therapy; inverse planning; plan optimization; quality assurance;
D O I
10.1118/1.1591194
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intensity-modulated radiation therapy (IMRT) represents one of the most significant technical advances in radiation therapy since the advent of the medical linear accelerator. It allows the clinical implementation of highly conformal nonconvex dose distributions. This complex but promising treatment modality is rapidly proliferating in both academic and community practice settings. However, these advances do not come without a risk. IMRT is not just an add-on to the current radiation therapy process; it represents a new paradigm that requires the knowledge of multimodality imaging, setup uncertainties and internal organ motion, tumor control probabilities, normal tissue complication probabilities, three-dimensional (3-D) dose calculation and optimization, and dynamic beam delivery of nonuniform beam intensities. Therefore, the purpose of this report is to guide and assist the clinical medical physicist in developing and implementing a viable and safe IMRT program. The scope of the IMRT program is quite broad, encompassing multileaf-collimator-based IMRT delivery systems, goal-based inverse treatment planning, and clinical implementation of IMRT with patient-specific quality assurance. This report, while not prescribing specific procedures, provides the framework and guidance to allow clinical radiation oncology physicists to make judicio us decisions in implementing a safe and efficient IMRT program in their clinics. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2089 / 2115
页数:27
相关论文
共 141 条
[1]  
Ayyangar K M, 2001, Med Dosim, V26, P29, DOI 10.1016/S0958-3947(00)00057-1
[2]   Quality assurance in IMRT: Importance of the transmission through the jaws for an accurate calculation of absolute doses and relative distributions [J].
Azcona, JD ;
Siochi, RAC ;
Azinovic, I .
MEDICAL PHYSICS, 2002, 29 (03) :269-274
[3]   Characterization of the output for helical delivery of intensity modulated slit beams [J].
Balog, JP ;
Mackie, TR ;
Reckwerdt, P ;
Glass, M ;
Angelos, L .
MEDICAL PHYSICS, 1999, 26 (01) :55-64
[4]   Optimization of the step-and-shoot leaf sequence for delivery of intensity modulated radiation therapy using a variable division scheme [J].
Beavis, AW ;
Ganney, PS ;
Whitton, VJ ;
Xing, L .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09) :2457-2465
[5]   Reduction of rectal dose by integration of the boost in the large-field treatment plan for prostate irradiation [J].
Bos, LJ ;
Damen, EMF ;
de Boer, RW ;
Mijnheer, BJ ;
McShan, DL ;
Fraass, BA ;
Kessler, ML ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01) :254-265
[6]   Theoretical considerations of monitor unit calculations for intensity modulated beam treatment planning [J].
Boyer, A ;
Xing, L ;
Ma, CM ;
Curran, B ;
Hill, R ;
Kania, A ;
Bleier, A .
MEDICAL PHYSICS, 1999, 26 (02) :187-195
[7]   Geometric analysis of light-field position of a multileaf collimator with curved ends [J].
Boyer, AL ;
Li, SD .
MEDICAL PHYSICS, 1997, 24 (05) :757-762
[8]   Modulated beam conformal therapy for head and neck tumors [J].
Boyer, AL ;
Geis, P ;
Grant, W ;
Carol, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :227-236
[9]   Intensity-modulated radiotherapy: Current status and issues of interest [J].
Boyer, AL ;
Butler, EB ;
DiPetrillo, TA ;
Engler, MJ ;
Fraass, B ;
Grant, W ;
Ling, CC ;
Low, DA ;
Mackie, TR ;
Mohan, R ;
Purdy, JA ;
Roach, M ;
Rosenman, JG ;
Verhey, LJ ;
Wong, JW ;
Cumberlin, RL ;
Stone, H ;
Palta, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :880-914
[10]   Intensity-modulated radiation therapy with dynamic multileaf collimators [J].
Boyer, AL ;
Yu, CX .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :48-59