Complementary on-line preconcentration strategies for steroids by capillary electrophoresis

被引:76
作者
Britz-McKibbin, P
Ichihashi, T
Tsubota, K
Chen, DDY
Terabe, S
机构
[1] Himeji Inst Technol, Grad Sch Sci, Kamigori, Hyogo 6781297, Japan
[2] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
基金
日本学术振兴会; 加拿大自然科学与工程研究理事会;
关键词
sample preparation; sweeping; dynamic pH; steroids;
D O I
10.1016/S0021-9673(03)00925-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Complementary on-line preconcentration strategies are needed when analyzing different classes of solutes in real samples by capillary electrophoresis (CE) with UV detection. The performance of three different on-line preconcentration (focusing) techniques under alkaline conditions was examined in terms of their selectivity and sensitivity enhancement for a group of steroids, including classes of androgens, corticosteroids and estrogens. Electrokinetic focusing of large sample injection plugs (up to 28% of effective capillary length or 22.1 cm) directly on-capillary can be tuned for specific classes of steroids based on changes in their mobility (velocity) using a multi-section electrolyte system in CE. A dynamic pH junction was applied for the selective resolution and focusing of weakly acidic estrogens using borate, pH 11.0 and pH 8.0 in the background electrolyte and the sample, respectively. Sweeping, using an anionic bile acid surfactant and neutral gamma-cyclodextrin (gamma-CD) under alkaline conditions (pH 8), resulted in focusing and separation of the moderately hydrophobic (non-ionic) classes of steroids, such as androgen and corticosteroids. Optimal focusing and resolution of all test steroids under a single buffer condition was realized by a dynamic pH junction-sweeping format using borate, pH 11.0 and bile acid surfactant with gamma-CD in the BGE, whereas the sample is devoid of surfactant at pH 8.0. The design of selective on-line focusing strategies in CE is highlighted by the analysis of microgram amounts of ethynyl estradiol derived from a female contraceptive pill extract using the dynamic pH junction method, which resulted in over a 100-fold enhancement in concentration sensitivity. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 76
页数:12
相关论文
共 44 条
[1]   Enantiomeric separation of local anaesthetic drugs by micellar electrokinetic capillary chromatography with taurodeoxycholate as chiral selector [J].
Amini, A ;
Beijersten, I ;
Pettersson, C ;
Westerlund, D .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (02) :301-313
[2]   Separating microbes in the manner of molecules. 1. Capillary electrokinetic approaches [J].
Armstrong, DW ;
Schulte, G ;
Schneiderheinze, JM ;
Westenberg, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (24) :5465-5469
[3]   ISOTACHOPHORESIS SUPERIMPOSED ON CAPILLARY ZONE ELECTROPHORESIS [J].
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY, 1993, 641 (02) :363-373
[4]   On-line focusing of flavin derivatives using dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection [J].
Britz-McKibbin, P ;
Otsuka, K ;
Terabe, S .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3736-3743
[5]   Picomolar analysis of flavins in biological samples by dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection [J].
Britz-McKibbin, P ;
Markuszewski, MJ ;
Iyanagi, T ;
Matsuda, K ;
Nishioka, T ;
Terabe, S .
ANALYTICAL BIOCHEMISTRY, 2003, 313 (01) :89-96
[6]   Sensitive and high-throughput analyses of purine metabolites by dynamic pH junction multiplexed capillary electrophoresis: A new tool for metabolomic studies [J].
Britz-McKibbin, P ;
Nishioka, T ;
Terabe, S .
ANALYTICAL SCIENCES, 2003, 19 (01) :99-104
[7]   Velocity-difference induced focusing of xanthine and purine metabolites by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
CHROMATOGRAPHIA, 2003, 57 (1-2) :87-93
[8]   Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1242-1252
[9]   Velocity-difference induced focusing of nucleotides in capillary electrophoresis with a dynamic pH junction [J].
Britz-McKibbin, P ;
Bebault, GM ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1729-1735
[10]   Analysis of epinephrine from fifteen different dental anesthetic formulations by capillary electrophoresis [J].
Britz-Mckibbin, P ;
Wong, J ;
Chen, DDY .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :535-540