A beamline for time resolved photoelectron microscopy on magnetic materials at the Swiss light source

被引:41
作者
Quitmann, C [1 ]
Flechsig, U
Patthey, L
Schmidt, T
Ingold, G
Howells, M
Janousch, M
Abela, R
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
关键词
photoelectron spectroscopy; magnetic surfaces;
D O I
10.1016/S0039-6028(01)00832-9
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We describe the "Surface/Interface: Microscopy" beamline currently under construction at the Paul Scherrer Institut. This beamline will use a photoemission electron microscope to study the electronic and magnetic structure of materials. Its photon energy range will be 94-2000 eV. To allow time resolved measurements with millisecond resolution we use a new scheme allowing to switch the photon helicity optically without perturbing the electron orbit. Two identical elliptical insertion devices are placed behind each other in the same straight section. They can produce light with opposing helicities. These two sources are separated horizontally by introducing a small static parallel offset in the electron orbit. Switching between the two rays of opposite helicities is done mechanically at the horizontal focus behind the monochromator. The two sources are brought to overlap on the sample by slightly defocussing the refocussing mirror. A commercial microscope (Deltax similar to 20 nm resolution) is adapted to the synchrotron by various upgrades. These include a software combining microscope and beamline control, a computer controlled mechanical alignment system, a separate sample preparation chamber, and sample cooling using liquid nitrogen. The beamline will be available for user operation in 2002. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:173 / 179
页数:7
相关论文
共 9 条
[1]  
DACH M, CONTROL DATA ACQUIST
[2]  
*ELMITEC, EL GMBH AM KAISER WI
[3]  
FLECHSIG U, IN PRESS P 7 INT C S
[4]  
Lovesey S W., 1996, X-Ray Scattering and Absorption by Magnetic Materials
[5]   Direct observation of the alignment of ferromagnetic spins by antiferromagnetic spins [J].
Nolting, F ;
Scholl, A ;
Stöhr, J ;
Seo, JW ;
Fompeyrine, J ;
Siegwart, H ;
Locquet, JP ;
Anders, S ;
Lüning, J ;
Fullerton, EE ;
Toney, MF ;
Scheinfein, MR ;
Padmore, HA .
NATURE, 2000, 405 (6788) :767-769
[6]   A novel undulator-based PGM beamline for circularly polarised synchrotron radiation at BESSY II [J].
Sawhney, KJS ;
Senf, F ;
Scheer, M ;
Schafers, F ;
Bahrdt, J ;
Gaupp, A ;
Gudat, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 390 (03) :395-402
[7]   A plane-grating monochromator for circularly polarized undulator radiation at BESSY II [J].
Senf, F ;
Sawhney, KJS ;
Follath, R ;
Scheer, M ;
Schafers, F ;
Bahrdt, J ;
Gaupp, A ;
Gudat, W .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :747-749
[8]  
Walker RP, 1998, PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3, P3527, DOI 10.1109/PAC.1997.753264
[9]  
Young A. T., 1996, Review of Scientific Instruments, V67