Dual-slot antennas for microwave tissue heating: Parametric design analysis and experimental validation

被引:63
作者
Brace, Christopher L. [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53792 USA
基金
美国国家卫生研究院;
关键词
thermal ablation; microwave ablation; interstitial antenna; IN-VIVO; RADIOFREQUENCY ABLATION; DIELECTRIC-PROPERTIES; SLEEVE ANTENNA; LUNG; SIZE; COMPLICATIONS; HYPERTHERMIA; CARCINOMA; CHOKE;
D O I
10.1118/1.3601019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: Design and validate an efficient dual-slot coaxial microwave ablation antenna that produces an approximately spherical heating pattern to match the shape of most abdominal and pulmonary tumor targets. Methods: A dual-slot antenna geometry was utilized for this study. Permutations of the antenna geometry using proximal and distal slot widths from 1 to 10 mm separated by 1-20 mm were analyzed using finite-element electromagnetic simulations. From this series, the most optimal antenna geometry was selected using a two-term sigmoidal objective function to minimize antenna reflection coefficient and maximize the diameter-to-length aspect ratio of heat generation. Sensitivities to variations in tissue properties and insertion depth were also evaluated in numerical models. The most optimal dual-slot geometry of the parametric analysis was then fabricated from semirigid coaxial cable. Antenna reflection coefficients at various insertion depths were recorded in ex vivo bovine livers and compared to numerical results. Ablation zones were then created by applying 50 W for 2-10 min in simulations and ex vivo livers. Mean zone diameter, length, aspect ratio, and reflection coefficients before and after heating were then compared to a conventional monopole antenna using ANOVA with post-hoc t-tests. Statistical significance was indicated for P < 0.05. Results: Antenna performance was highly sensitive to dual-slot geometry. The best-performing designs utilized a proximal slot width of 1 mm, distal slot width of 4 mm +/- 1 mm and separation of 8 mm +/- 1 mm. These designs were characterized by an active choking mechanism that focused heating to the distal tip of the antenna. A dual-band resonance was observed in the most optimal design, with a minimum reflection coefficient of -20.9 dB at 2.45 and 1.25 GHz. Total operating bandwidth was greater than 1 GHz, but the desired heating pattern was achieved only near 2.45 GHz. As a result, antenna performance was robust to changes in insertion depth and variations in relative permittivity of the surrounding tissue medium. In both simulations and ex vivo liver, the dual-slot antenna created ablations greater in diameter than a coaxial monopole (35 mm +/- 2 mm versus 31 mm +/- 2 mm; P < 0.05), while also shorter in length (49 mm +/- 2 mm versus 60 mm +/- 6 mm; P < 0.001) after 10 min. Similar results were obtained after 2 and 5 min as well. Conclusions: Dual-slot antennas can produce more spherical ablation zones while retaining low reflection coefficients. These benefits are obtained without adding to the antenna diameter. Further evaluation for clinical microwave ablation appears warranted. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3601019]
引用
收藏
页码:4232 / 4240
页数:9
相关论文
共 33 条
[1]
Radiofrequency and Microwave Ablation of Lung Tumors [J].
Abbas, Ghulam ;
Pennathur, Arjun ;
Landreneau, Rodney J. ;
Luketich, James D. .
JOURNAL OF SURGICAL ONCOLOGY, 2009, 100 (08) :645-650
[2]
Microwaves create larger ablations than radiofrequency when controlled for power in ex vivo tissue [J].
Andreano, A. ;
Huang, Yu ;
Meloni, M. Franca ;
Lee, Fred T., Jr. ;
Brace, Christopher .
MEDICAL PHYSICS, 2010, 37 (06) :2967-2973
[3]
[Anonymous], 1990, PHYS PROPERTIES TISS
[4]
A review of coaxial-based interstitial antennas for hepatic microwave ablation [J].
Bertram, John M. ;
Yang, Deshan ;
Converse, Mark C. ;
Webster, John G. ;
Mahvi, David M. .
Critical Reviews in Biomedical Engineering, 2006, 34 (03) :187-213
[5]
Temperature-dependent dielectric properties of liver tissue measured during thermal ablation: Toward an improved numerical model [J].
Brace, Christopher L. .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :230-233
[6]
Microwave Ablation Technology: What Every User Should Know [J].
Brace, Christopher L. .
CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2009, 38 (02) :61-67
[7]
Microwave ablation with a triaxial antenna:: Results in ex vivo bovine liver [J].
Brace, CL ;
Laeseke, PF ;
van der Weide, DW ;
Lee, FT .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2005, 53 (01) :215-220
[8]
CONVERSE MC, 2009, ANTENNAS PROPAGATION, V57, P559
[9]
Radiofrequency thermal ablation: Computer analysis of the size of the thermal injury created by overlapping ablations [J].
Dodd, GD ;
Frank, MS ;
Aribandi, M ;
Chopra, S ;
Chintapalli, KN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (04) :777-782
[10]
Microwave ablation with triaxial antennas tuned for lung: Results in an in vivo porcine model [J].
Durick, Nathan A. ;
Laeseke, Paul F. ;
Broderick, Lynn S. ;
Lee, Fred T., Jr. ;
Sampson, Lisa A. ;
Frey, Tina M. ;
Warner, Thomas F. ;
Fine, Jason P. ;
Van der Weide, Daniel W. ;
Brace, Christopher L. .
RADIOLOGY, 2008, 247 (01) :80-87