Detection of Salmonella enterica serovar typhimurium by using a rapid, array-based immunosensor

被引:61
作者
Taitt, CR
Shubin, YS
Angel, R
Ligler, FS
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
[2] Univ Maryland, Dept Poultry Sci, College Pk, MD 20742 USA
关键词
D O I
10.1128/AEM.70.1.152-158.2004
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The multianalyte array biosensor (MAAB) is a rapid analysis instrument capable of detecting multiple analytes simultaneously. Rapid (15-min), single-analyte sandwich immunoassays were developed for the detection of Salmonella enterica serovar Typhimurium, with a detection limit of 8 X 10(4) CFU/ml; the limit of detection was improved 10-fold by lengthening the assay protocol to 1 h. S. enterica serovar Typhimurium was also detected in the following spiked foodstuffs, with minimal sample preparation: sausage, cantaloupe, whole liquid egg, alfalfa sprouts, and chicken carcass rinse. Cross-reactivity tests were performed with Escherichia coli and Campylobacter jejuni. To determine whether the MAAB has potential as a screening tool for the diagnosis of asymptomatic Salmonella infection of poultry, chicken excretal samples from a private, noncommercial farm and from university poultry facilities were tested. While the private farm excreta gave rise to signals significantly above the buffer blanks, none of the university samples tested positive for S. enterica serovar Typhimurium without spiking; dose-response curves of spiked excretal samples from university-raised poultry gave limits of detection of 8 x 10(3) CFU/g.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 72 条
[1]   Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor [J].
Anderson, GP ;
Nerurkar, NL .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 271 (1-2) :17-24
[2]  
ANDREWS CD, 2001, USDA FSIS MICROBIOLO, P4
[3]  
ANDREWS WH, 2001, BACTERIOLOGICAL ANAL
[4]  
Olsen S J, 2000, MMWR CDC Surveill Summ, V49, P1
[5]   Piezoelectric flow injection analysis biosensor for the detection of Salmonella typhimurium [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, A .
JOURNAL OF FOOD SCIENCE, 2002, 67 (01) :314-320
[6]   Detection of Salmonella cells within 24 to 26 hours in poultry samples with the polymerase chain reaction BAX system [J].
Bailey, JS .
JOURNAL OF FOOD PROTECTION, 1998, 61 (07) :792-795
[7]   Sample preparation methods for PCR detection of Escherichia coli O157:H7, Salmonella typhimurium, and Listeria monocytogenes on beef chuck shoulder using a single enrichment medium [J].
Bhaduri, S ;
Cottrell, B .
MOLECULAR AND CELLULAR PROBES, 2001, 15 (05) :267-274
[8]   Simultaneous detection of Escherichia coli O157:H7, Listeria monocytogenes and Salmonella strains by real-time PCR [J].
Bhagwat, AA .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2003, 84 (02) :217-224
[9]  
BLASER MJ, 1982, REV INFECT DIS, V4, P1096
[10]   Immunoassays based on surface enhanced infrared absorption spectroscopy [J].
Brown, CW ;
Li, Y ;
Seelenbinder, JA ;
Pivarnik, P ;
Rand, AG ;
Letcher, SV ;
Gregory, OJ ;
Platek, MJ .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2991-2996