Biophysical characterization of skin damage and recovery after exposure to different surfactants

被引:60
作者
Bárány, E
Lindberg, M
Lodén, M
机构
[1] ACO HUD AB, R&D, S-18215 Danderyd, Sweden
[2] Univ Uppsala Hosp, Dept Dermatol, S-75185 Uppsala, Sweden
关键词
surfactants; irritant contact dermatitis; bioengineering methods; barrier function; recovery time;
D O I
10.1111/j.1600-0536.1999.tb05999.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
The majority of adverse skin reactions to personal-care products are presumed to be caused by irritant substances, like surfactants. In this study, different aspects of the irritant reaction after a single exposure to 8 surfactants were characterized during 2 weeks. Solutions of 2% sodium lauryl sulfate, 5% sodium C12-15 pareth sulfate, 5% sodium cocoyl isethionate, 10% disodium laureth sulfosuccinate, 10% sodium cocoamphoacetate, 10% cocamide DEA, 10% cocamidopropyl betaine and 10% lauryl glucoside, respectively, were applied to the forearm of 12 volunteers. Clinical assessment, an evaporimeter, a laser Doppler flowmeter and a corneometer were used for evaluation. The surfactants induced different degrees of irritation. Erythema, transepidermal water loss and skin blood flow exhibited a similar time course, which seemed to be inversely related to the delayed scaling and reduced skin capacitance. The mechanism of the damaging effect of the surfactants seems to be similar, although some minor differences were noted.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 35 条
[1]   SODIUM LAURYL SULFATE FOR IRRITANT PATCH TESTING - A DOSE-RESPONSE STUDY USING BIOENGINEERING METHODS FOR DETERMINATION OF SKIN IRRITATION [J].
AGNER, T ;
SERUP, J .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1990, 95 (05) :543-547
[2]   SKIN REACTIONS TO IRRITANTS ASSESSED BY NON-INVASIVE BIOENGINEERING METHODS [J].
AGNER, T ;
SERUP, J .
CONTACT DERMATITIS, 1989, 20 (05) :352-359
[3]   Adverse effects of cosmetics and toiletries reported to the Swedish Medical Products Agency 1989-1994 [J].
Berne, B ;
Bostrom, A ;
Grahnen, AF ;
Tammela, M .
CONTACT DERMATITIS, 1996, 34 (05) :359-362
[4]  
BLAKEHASKINS JC, 1986, J SOC COSMET CHEM, V37, P199
[5]  
Courage W., 1994, Bioengeneering of the skin: water and the stratum corneum, P171
[6]  
De Groot AC, 1988, INT J COSMETIC SCI, V9, P255
[7]  
FAUCHER JA, 1978, J SOC COSMET CHEM, V29, P323
[8]   SOAP CHAMBER TEST - NEW METHOD FOR ASSESSING THE IRRITANCY OF SOAPS [J].
FROSCH, PJ ;
KLIGMAN, AM .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1979, 1 (01) :35-41
[9]   COMPARISON OF IN-VITRO PREDICTIVE TESTS FOR IRRITATION INDUCED BY ANIONIC SURFACTANTS [J].
GOFFIN, V ;
PAYE, M ;
PIERARD, GE .
CONTACT DERMATITIS, 1995, 33 (01) :38-41
[10]  
HOLM S, 1979, SCAND J STAT, V6, P65