Luminescence detection with a liquid care waveguide

被引:93
作者
Dasgupta, PK [1 ]
Zhang, GF [1 ]
Li, JZ [1 ]
Boring, CB [1 ]
Jambunathan, S [1 ]
Al-Horr, R [1 ]
机构
[1] Texas Tech Univ, Dept Chem & Biochem, Lubbock, TX 79409 USA
关键词
D O I
10.1021/ac981260q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new fluoropolymer tube is proposed as the basis of a novel class of liquid core waveguide-based luminescence detectors. Both chemiluminescence and photoluminescence detectors are possible, In the latter case, illumination is transverse to the main axis of the tube. With such a geometry, it is even possible to operate without monochromators, although limits of detection do improve with the incorporation of monochromators. The nature of the design is such that it is particularly simple to fabricate detectors in a now-through configuration and where the light from the cell is coupled to a photodetector by an optical fiber. No focusing optics are necessary. A number of applications are illustrated. Attainable limits (LODs, S/N = 3) of detection include 150 pM fluorescein with a 254-mn excitation source, 200 amol of fluorescein in a capillary electrophoresis setup with excitation by two blue light-emitting diodes, 35 nM NH3 as the isoindole derivative in a now injection analysis system using a photodiode detector, 50 nM methylene blue and 1 nM Rhodamine 560 using respectively red and green LED arrays and an avalanche photodiode and a PMT in a FIA configuration, 100 parts per trillion by volume gaseous formaldehyde as the Hantzsch reaction product with cyclohexanedione using a diffusion scrubber, 2.7 mu M and 17 nM hypochlorite based on its chemiluminescence reaction with luminol with photodiode and PMT detectors, respectively, and 1 ppm SO42- based on nephelometric detection at 470 nm, The approach described herein leads to particularly simple and inexpensive luminescence detectors with excellent sensitivity.
引用
收藏
页码:1400 / 1407
页数:8
相关论文
共 23 条
[1]   Waveguide capillary cell for low-refractive-index liquids [J].
Altkorn, R ;
Koev, I ;
Gottlieb, A .
APPLIED SPECTROSCOPY, 1997, 51 (10) :1554-1558
[2]  
BALCIUNAS RT, 1981, THESIS MICHIGAN STAT
[3]   SCINTILLATOR-FIBER CHARGED-PARTICLE TRACK-IMAGING DETECTOR [J].
BINNS, WR ;
ISRAEL, MH ;
KLARMANN, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 216 (03) :475-480
[4]   An affordable high-performance optical absorbance detector for capillary systems [J].
Boring, CB ;
Dasgupta, PK .
ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) :123-132
[5]   An innovative way of obtaining room-temperature phosphorescence signals in solution [J].
Carretero, AS ;
Blanco, CC ;
Díaz, BC ;
Gutiérrez, AF .
ANALYTICA CHIMICA ACTA, 1998, 361 (03) :217-222
[6]   High-sensitivity gas sensors based on gas-permeable liquid core waveguides and long-path absorbance detection [J].
Dasgupta, PK ;
Genfa, Z ;
Poruthoor, SK ;
Caldwell, S ;
Dong, S ;
Liu, SY .
ANALYTICAL CHEMISTRY, 1998, 70 (22) :4661-4669
[7]  
*DUP FLUR, 1999, H165771 DUP FLUR
[8]   CONTINUOUS AUTOMATED-DETERMINATION OF ATMOSPHERIC FORMALDEHYDE AT THE PARTS-PER-TRILLION LEVEL [J].
FAN, Q ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :551-556
[9]   SIDE-VIEW TYPE OF WAVE-GUIDE FLOW CELLS FOR FLUOROMETRY AS A DETECTOR FOR FLOW-INJECTION ANALYSIS OF LEAD [J].
FUJIWARA, K ;
ITO, S ;
KOJYO, RE ;
TSUBOTA, H ;
CARTER, RL .
APPLIED SPECTROSCOPY, 1992, 46 (06) :1032-1039
[10]   APPLICATION OF WAVE-GUIDING IN SOLUTIONS FOR ABSORPTION AND FLUORESCENCE SPECTROMETRY [J].
FUJIWARA, K ;
ITO, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1991, 10 (06) :184-190