Optimal ECG trigger point in electron-beam CT studies: Three methods for minimizing motion artifacts

被引:38
作者
Mao, SS [1 ]
Budoff, MJ [1 ]
Bin, L [1 ]
Liu, SCK [1 ]
机构
[1] Univ Calif Los Angeles, Harbor Res & Educ Inst, Torrance, CA 90502 USA
关键词
computed tomography (CT); artifact; electron beam; coronary vessels; CT;
D O I
10.1016/S1076-6332(03)80722-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors hypothesized that electrocardiographic triggering near end systole could minimize motion artifacts in electron-beam computed tomography (CT) of the coronary artery. Materials and Methods. The study included 2,660 patients who underwent coronary artery calcium scanning with electron-beam CT. Trigger times were as follows: end of T wave. 120 to 25 msec before end of T wave, 25-50 msec after end of T wave, 40%, 45%, 50%, 55%, 60%, 70%, 75%, 80%, 90%, and 100% of R-R interval. The authors divided each group into seven subgroups according to heart rate. The percentages of cases with motion artifact in the right coronary artery were computed. Optimal trigger times were defined for each group, as well as for scan acquisitions of 250 and 200 msec. Results. The optimal trigger times were as follows for heart rates of less than 50, 51-60, 61-70, 71-80, 81-90, 91-100, and more than 100 beats per minute, respectively: for 100-msec scans, 359 (27% of the R-R interval), 228 (31%), 314 (34%), 304 (38%), 289 (41%), 283 (45%), and 274 msec (48%) after the R wave; for 250-msec scans, 840 (63%), 654 (60%), 240 (26%), 224 (28%), 219 (31%), 208 (33%), and 200 msec (35%) after the R wave; and for 200-msec scans, 722 (65%), 687 (63%), 249 (27%), 248 (31%), 244 (35%), 233 (37%), and 223 msec (39%) after the R wave. Conclusion. The use of these new electrocardiographic triggers before end systole yielded the lowest percentage of motion artifacts (<3% across all heart rates), much lower than for conventional triggers (51% of cases with motion artifact for 80% trigger, P < .001).
引用
收藏
页码:1107 / 1115
页数:9
相关论文
共 31 条
[1]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]   Comparison of two different software systems for electron-beam CT-derived quantification of coronary calcification [J].
Adamzik, M ;
Schmermund, A ;
Reed, JE ;
Adamzik, S ;
Behrenbeck, T ;
Sheedy, PF .
INVESTIGATIVE RADIOLOGY, 1999, 34 (12) :767-773
[4]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[5]   Preview method for electron-beam CT scanning of the coronary arteries [J].
Bakhsheshi, H ;
Mao, SS ;
Budoff, MJ ;
Bin, L ;
Brundage, BH .
ACADEMIC RADIOLOGY, 2000, 7 (08) :620-626
[6]   Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification [J].
Becker, CR ;
Jakobs, TF ;
Aydemir, S ;
Becker, A ;
Knez, A ;
Schoepf, UJ ;
Bruening, R ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :543-547
[7]   Electron beam computed tomography: Screening for coronary artery disease [J].
Budoff, MJ ;
Brundage, BH .
CLINICAL CARDIOLOGY, 1999, 22 (09) :554-558
[8]   Intravenous three-dimensional coronary angiography using contrast enhanced electron beam computed tomography [J].
Budoff, MJ ;
Oudiz, RJ ;
Zalace, CP ;
Bakhsheshi, H ;
Goldberg, SL ;
French, WJ ;
Rami, TG ;
Brundage, BH .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (06) :840-845
[9]   Simple single-section method for measurement of left and right atrial volumes with electron-beam CT [J].
Budoff, MJ ;
Mao, SS ;
Wang, SJ ;
Bakhsheshi, H ;
Brundage, BH .
ACADEMIC RADIOLOGY, 1999, 6 (08) :481-486
[10]   Comparison of spiral and electron beam tomography in the evaluation of coronary calcification in asymptomatic persons [J].
Budoff, MJ ;
Mao, SS ;
Zalace, CP ;
Bakhsheshi, H ;
Oudiz, RJ .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2001, 77 (2-3) :181-188