Direct coronary stenting: Effect on coronary blood flow, immediate and late clinical results

被引:60
作者
Capozzolo, C [1 ]
Piscione, F [1 ]
De Luca, G [1 ]
Cioppa, A [1 ]
Mazzarotto, P [1 ]
Leosco, D [1 ]
Golino, P [1 ]
Indolfi, C [1 ]
Chiariello, M [1 ]
机构
[1] Univ Naples Federico II, Div Cardiol, I-80131 Naples, Italy
关键词
coronary angioplasty; stent; TIMI frame count; cost containment;
D O I
10.1002/ccd.1204
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Direct stenting (DS) was attempted in 99 coronary lesions in 94 patients while standard stenting (SS) was attempted in 113 lesions in 103 patients matched for clinical characteristics, stenosis type, and location and stent type. The angiographic result was also evaluated according to TIMI frame count method (TFC) before and after procedure. A clinical follow-up was performed 1 year after the procedure. Before the procedure, TIMI grade 3 flow was detected in 42 cases (42.4%), grade 2 in 40 cases (40.4%), grade 1 in 5 cases (5.1 %), and grade 0 in 12 cases (12.1 %) in the DS group; these data were similar in SS group. After the procedure, TIMI grade flow was 3 in 90 cases (92.8%) in DS group and in 87 (77.0%) in SS group (P < 0.005); grade 2 was observed in 7 case (7.2%) in DS group and in 25 (22.1 %) in SS group (P < 0.005). Major adverse cardiac events during hospitalization and at follow-up were similar in two groups. Radiation exposure time and procedure costs per lesion were significantly reduced in DS group compared to SS group (10.1 8 min vs. 13.9 4.7 min, P < 0.001; and 1901 +/- 687 Euro vs. 2352 +/- 743 Euro, P < 0.001, respectively). This study confirms that, in selected patients, direct stenting is a safe and successful procedure, allowing a significant reduction in radiation exposure time and procedural costs compared to standard stenting technique. The angiographic success is confirmed by the improvement in TFC in all cases. (C) Wiley-Liss, Inc.
引用
收藏
页码:464 / 473
页数:10
相关论文
共 28 条
[11]  
Figulla HR, 1998, CATHETER CARDIO DIAG, V43, P245, DOI 10.1002/(SICI)1097-0304(199803)43:3<245::AID-CCD1>3.0.CO
[12]  
2-9
[13]  
FISHMANN DL, 1994, NEW ENGL J MED, V331, P495
[14]   PATTERNS IN VISUAL INTERPRETATION OF CORONARY ARTERIOGRAMS AS DETECTED BY QUANTITATIVE CORONARY ARTERIOGRAPHY [J].
FLEMING, RM ;
KIRKEEIDE, RL ;
SMALLING, RW ;
GOULD, KL ;
STUART, Y .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (04) :945-951
[15]   TIMI frame count: A quantitative method of assessing coronary artery flow [J].
Gibson, CM ;
Cannon, CP ;
Daley, WL ;
Dodge, JT ;
Alexander, B ;
Marble, SJ ;
McCabe, CH ;
Raymond, L ;
Fortin, T ;
Poole, WK ;
Braunwald, E .
CIRCULATION, 1996, 93 (05) :879-888
[16]   Direct coronary stenting without balloon predilation in acute coronary syndromes [J].
Hamon, M ;
Richardeau, Y ;
Lécluse, E ;
Saloux, E ;
Sabatier, R ;
Agostini, D ;
Filmont, JE ;
Grollier, G ;
Potier, JC .
AMERICAN HEART JOURNAL, 1999, 138 (01) :55-59
[17]   SMOOTH-MUSCLE CELL-PROLIFERATION IS PROPORTIONAL TO THE DEGREE OF BALLOON INJURY IN A RAT MODEL OF ANGIOPLASTY [J].
INDOLFI, C ;
ESPOSITO, G ;
DILORENZO, E ;
RAPACCIUOLO, A ;
FELICIELLO, A ;
PORCELLINI, A ;
AVVEDIMENTO, VE ;
CONDORELLI, M ;
CHIARIELLO, M .
CIRCULATION, 1995, 92 (05) :1230-1235
[18]   REVIEW OF RADIATION SAFETY IN THE CARDIAC-CATHETERIZATION LABORATORY [J].
JOHNSON, LW ;
MOORE, RJ ;
BALTER, S .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 25 (03) :186-194
[19]  
Kastrati A, 2000, CIRCULATION, V102, P2593
[20]   Determination of angiographic (TIMI grade) blood flow by intracoronary Doppler flow velocity during acute myocardial infarction [J].
Kern, MJ ;
Moore, JA ;
Aguirre, FV ;
Bach, RG ;
Caracciolo, EA ;
Wolford, T ;
Khoury, AF ;
Mechem, C ;
Donohue, TJ .
CIRCULATION, 1996, 94 (07) :1545-1552