共 19 条
Measurement of Focal Ground-glass Opacity Diameters on CT Images: Interobserver Agreement in Regard to Identifying Increases in the Size of Ground-Glass Opacities
被引:45
作者:
Kakinuma, Ryutaro
[1
]
Ashizawa, Kazuto
[2
]
Kuriyama, Keiko
[3
]
Fukushima, Aya
[4
]
Ishikawa, Hiroyuki
[5
]
Kamiya, Hisashi
[6
]
Koizumi, Naoya
[7
]
Maruyama, Yuichiro
[8
]
Minami, Kazunori
[4
]
Nitta, Norihisa
[9
]
Oda, Seitaro
[10
]
Oshiro, Yasuji
[11
]
Kusumoto, Masahiko
[12
]
Murayama, Sadayuki
[6
]
Murata, Kiyoshi
[9
]
Muramatsu, Yukio
[1
]
Moriyama, Noriyuki
[1
]
机构:
[1] Res Ctr Canc Prevent & Screening, Natl Canc Ctr, Chuo Ku, Tokyo, Japan
[2] Nagasaki Univ Hosp, Clin Oncol Ctr, Nagasaki, Japan
[3] Osaka Med Ctr, Dept Radiol, Osaka, Japan
[4] Nagasaki Univ, Div Radiol & Radiat Biol, Grad Sch Biomed Sci, Nagasaki, Japan
[5] Niigata Univ, Med & Dent Hosp, Dept Radiol, Niigata 95021, Japan
[6] Univ Ryukyus, Dept Radiol, Sch Med, Nishihara, Okinawa 90301, Japan
[7] Niigata Canc Ctr, Dept Radiol, Niigata, Japan
[8] Komoro Kousei Gen Hosp, Dept Radiol, Komoro, Japan
[9] Shiga Univ Med Sci, Dept Radiol, Shiga, Japan
[10] Kumamoto Univ, Dept Diagnost Radiol, Grad Sch Med Sci, Kumamoto 860, Japan
[11] Natl Okinawa Hosp, Dept Radiol, Okinawa, Japan
[12] Natl Canc Ctr Hosp, Div Diagnost Radiol, Kashiwa, Chiba, Japan
关键词:
Lung;
ground-glass opacity;
computed tomography;
diameter;
interobserver agreement;
THIN-SECTION CT;
PULMONARY NODULES;
BRONCHIOLOALVEOLAR CARCINOMA;
PERIPHERAL ADENOCARCINOMAS;
FOLLOW-UP;
MANAGEMENT;
LESIONS;
D O I:
10.1016/j.acra.2011.12.002
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
100231 [临床病理学];
100902 [航空航天医学];
摘要:
Purpose: To evaluate interobserver agreement in regard to measurements of focal ground-glass opacities (GGO) diameters on computed tomography (CT) images to identify increases in the size of GGOs. Materials and Methods: Approval by the institutional review board and informed consent by the patients were obtained. Ten GGOs (mean size, 10.4 mm; range, 6.5-15 mm), one each in 10 patients (mean age, 65.9 years; range, 58-78 years), were used to make the diameter measurements. Eleven radiologists independently measured the diameters of the GGOs on a total of 40 thin-section CT images (the first [n = 10], the second [n = 10], and the third [n = 10] follow-up CT examinations and remeasurement of the first [n = 10] follow-up CT examinations) without comparing time-lapse CT images. Interobserver agreement was assessed by means of Bland-Altman plots. Results: The smallest range of the 95% limits of interobserver agreement between the members of the 55 pairs of the 11 radiologists in regard to maximal diameter was -1.14 to 1.72 mm, and the largest range was -7.7 to 1.7 mm. The mean value of the lower limit of the 95% limits of agreement was -3.1 +/- 1.4 mm, and the mean value of their upper limit was 2.5 +/- 1.1 mm. Conclusion: When measurements are made by any two radiologists, an increase in the length of the maximal diameter of more than 1.72 mm would be necessary in order to be able to state that the maximal diameter of a particular GGO had actually increased.
引用
收藏
页码:389 / 394
页数:6
相关论文

