Pulmonary Ground-Glass Nodules: Increase in Mass as an Early Indicator of Growth

被引:193
作者
de Hoop, Bartjan [1 ]
Gietema, Hester [1 ,3 ]
van de Vorst, Saskia [1 ]
Murphy, Keelin [2 ]
van Klaveren, Rob J. [4 ]
Prokop, Mathias [1 ]
机构
[1] Univ Med Ctr, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[3] Meander Med Ctr, Dept Radiol, Amersfoort, Netherlands
[4] Erasmus MC, Dept Pulmonol, Rotterdam, Netherlands
关键词
PERIPHERAL LUNG ADENOCARCINOMAS; AUTOMATED CT VOLUMETRY; HIGH-RESOLUTION CT; THIN-SECTION CT; COMPUTED-TOMOGRAPHY; HISTOLOGIC CHARACTERISTICS; SCREENING TRIAL; FOLLOW-UP; CANCER; OPACITY;
D O I
10.1148/radiol.09090571
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare manual measurements of diameter, volume, and mass of pulmonary ground-glass nodules (GGNs) to establish which method is best for identifying malignant GGNs by determining change across time. Materials and Methods: In this ethics committee-approved retrospective study, baseline and follow-up CT examinations of 52 GGNs detected in a lung cancer screening trial were included, resulting in 127 GGN data sets for evaluation. Two observers measured GGN diameter with electronic calipers, manually outlined GGNs to obtain volume and mass, and scored whether a solid component was present. Observer 1 repeated all measurements after 2 months. Coefficients of variation and limits of agreement were calculated by using Bland-Altman methods. In a subgroup of GGNs containing all resected malignant lesions, the ratio between intraobserver variability and growth (growth-to-variability ratio) was calculated for each measurement technique. In this subgroup, the mean time for growth to exceed the upper limit of agreement of each measurement technique was determined. Results: The kappa values for intra-and interobserver agreement for identifying a solid component were 0.55 and 0.38, respectively. Intra-and interobserver coefficients of variation were smallest for GGN mass (P < .001). Thirteen malignant GGNs were resected. Mean growth-to-variability ratios were 11, 28, and 35 for diameter, volume, and mass, respectively (P = .03); mean times required for growth to exceed the upper limit of agreement were 715, 673, and 425 days, respectively (P = .02). Conclusion: Mass measurements can enable detection of growth of GGNs earlier and are subject to less variability than are volume or diameter measurements. (C) RSNA, 2010
引用
收藏
页码:199 / 206
页数:8
相关论文
共 27 条
[1]   Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time [J].
Aoki, T ;
Nakata, H ;
Watanabe, H ;
Nakamura, K ;
Kasai, T ;
Hashimoto, H ;
Yasumoto, K ;
Kido, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) :763-768
[2]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
COHEN J, 1960, EDUC PSYCHOL MEAS, V20, P46
[5]   Monitoring of smoking-induced emphysema with CT in a lung cancer screening setting: Detection of real increase in extent of emphysema [J].
Gietema, Hester A. ;
Schilham, Arnold M. ;
van Ginneken, Bram ;
van Klaveren, Rob J. ;
Lammers, Jan Willem J. ;
Prokop, Mathias .
RADIOLOGY, 2007, 244 (03) :890-897
[6]   Growth rate of small lung cancers detected on mass CT screening [J].
Hasegawa, M ;
Sone, S ;
Takashima, S ;
Li, F ;
Yang, ZG ;
Maruyama, Y ;
Watanabe, T .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876) :1252-1259
[7]   CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules [J].
Henschke, CI ;
Yankelevitz, DF ;
Mirtcheva, R ;
McGuinness, G ;
McCauley, D ;
Miettinen, OS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) :1053-1057
[8]   Coronary artery calcium: Accuracy and reproducibility of measurements with multi-detector row CT - Assessment of effects of different thresholds and quantification methods [J].
Hong, C ;
Bae, KT ;
Pilgram, TK .
RADIOLOGY, 2003, 227 (03) :795-801
[9]   Progression of focal pure ground-glass opacity detected by low-dose helical computed tomography screening for lung cancer [J].
Kakinuma, R ;
Ohmatsu, H ;
Kaneko, M ;
Kusumoto, M ;
Yoshida, J ;
Nagai, K ;
Nishiwaki, Y ;
Kobayashi, T ;
Tsuchiya, R ;
Nishyama, H ;
Matsui, E ;
Eguchi, K ;
Moriyama, N .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (01) :17-23
[10]   Natural history of pure ground-glass opacity after long-term follow-up of more than 2 years [J].
Kodama, K ;
Higashiyama, M ;
Yokouchi, H ;
Takami, K ;
Kuriyama, K ;
Kusunoki, Y ;
Nakayama, T ;
Imamura, F .
ANNALS OF THORACIC SURGERY, 2002, 73 (02) :386-392