Coronary artery calcium: Accuracy and reproducibility of measurements with multi-detector row CT - Assessment of effects of different thresholds and quantification methods

被引:139
作者
Hong, C [1 ]
Bae, KT [1 ]
Pilgram, TK [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
computed tomography (CT); experimental studies; coronary vessels; calcification; CT; phantoms;
D O I
10.1148/radiol.2273020369
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effects of different thresholds and quantification methods on the accuracy and reproducibility of coronary calcium measurements with multi-detector row computed tomography (CT). MATERIALS AND METHODS: A cardiac CT phantom containing predetermined calcified cylinders was scanned. Calcium volume and mass were measured at various threshold values ranging from 80 to 230 HU. In 32 patients, two consecutive CT scans were obtained, and the coronary artery calcium score, volume, and mass were measured by one observer at 130- and 90-HU thresholds. Correlation analysis and analysis of variance were performed to evaluate the measurement errors in the phantom study and the interscan variability in the clinical study. RESULTS: In the phantom, mass measurement error varied with threshold and calcium density (P < .01). Mass error was strongly correlated with volume error (r = 0.91, P < .01) but with a much smaller range. In the clinical study, interscan variability of mass measurements was significantly lower than that with other measurement methods for both patients and individual vessels. For the patients, the mean interscan variability of calcium score, volume, and mass at the 130-HU threshold was 20.4%, 13.9%, and 9.3%, respectively. For all methods, interscan variability was not significantly different between the 130- and 90-HU thresholds (P > .05). CONCLUSION: The mass measurement is more accurate, less variable, and more reproducible in coronary calcium quantification than are measurements with other algorithms. Accurate quantification of calcium in each calcified plaque may require that the threshold be set individually, depending on the calcium density. (C) RSNA, 2003.
引用
收藏
页码:795 / 801
页数:7
相关论文
共 24 条
[1]   Variability of repeated coronary artery calcium measurements by electron beam tomography [J].
Achenbach, S ;
Ropers, D ;
Möhlenkamp, S ;
Schmermund, A ;
Muschiol, G ;
Groth, J ;
Kusus, M ;
Regenfus, M ;
Daniel, WG ;
Erbel, R ;
Moshage, W .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :210-+
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]   Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP [J].
Becker, CR ;
Kleffel, T ;
Crispin, A ;
Knez, A ;
Young, J ;
Schoepf, UJ ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1295-1298
[4]   SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE [J].
BIELAK, LF ;
KAUFMANN, RB ;
MOLL, PP ;
MCCOLLOUGH, CH ;
SCHWARTZ, RS ;
SHEEDY, PF .
RADIOLOGY, 1994, 192 (03) :631-636
[5]   CORONARY-ARTERY CALCIFICATION DETECTED WITH ULTRAFAST CT AS AN INDICATION OF CORONARY-ARTERY DISEASE - WORK IN PROGRESS [J].
BREEN, JF ;
SHEEDY, PF ;
SCHWARTZ, RS ;
STANSON, AW ;
KAUFMANN, RB ;
MOLL, PP ;
RUMBERGER, JA .
RADIOLOGY, 1992, 185 (02) :435-439
[6]   Measurement of coronary artery calcium with dual-slice helical CT compared with coronary angiography: Evaluation of CT scoring methods, interobserver variations, and reproducibility [J].
Broderick, LS ;
Shemesh, J ;
Wilensky, RL ;
Eckert, GJ ;
Zhou, XH ;
Torres, WE ;
Balk, MA ;
Rogers, WJ ;
Conces, DJ ;
Kopecky, KK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :439-444
[7]   Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography [J].
Callister, TQ ;
Raggi, P ;
Cooil, B ;
Lippolis, NJ ;
Russo, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1972-1978
[8]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[9]   Evaluation of subsecond gated helical CT for quantification of coronary artery calcium and comparison with electron beam CT [J].
Carr, JJ ;
Crouse, JR ;
Goff, DC ;
D'Agostino, RB ;
Peterson, NP ;
Burke, GL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :915-921
[10]  
Detrano R, 1995, Am J Card Imaging, V9, P167