An efficient method for small field treatment dose calculation for stereotactic radiosurgery using a LINAC

被引:2
作者
Lam, CF [1 ]
Zhu, JG
机构
[1] Med Univ S Carolina, Dept Biometry & Epidemiol, Charleston, SC 29425 USA
[2] MultiData Corp, St Louis, MO 63119 USA
关键词
dose calculation; optimization; adaptive sampling;
D O I
10.1118/1.598251
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The normal procedure for a physician-physicist team designing a treatment plan for multiarc stereotactic radiosurgery is the trial-and-error approach of changing the collimator size and the location of the isocenter of radiation and viewing the isodose curves on two-dimensional computed tomography (CT) or magnetic resonance imaging (MRI) image planes. Automatic optimization procedures have also been used to optimize beam weight or beam size. However, either process is very time consuming. To improve the speed of the dose calculation, a random sampling method has been proposed. Unfortunately, the sampled values of an objective function are different from one sample to another. Such a sampling method cannot be used in automatic optimization because the next move in an optimization process is based on the current and past objective function values. To this end, an adaptive method based on the size of the collimators is proposed and used to determine a small volume in the shape of a hollow sphere for which the dose is calculated. With an appropriate choice of an adaptive hollow sphere, the objective function calculated based on such a hollow sphere is the same as that calculated with the traditional three-dimensional (3-D) cube matrix. However, with the new adaptive method, the speed of calculating a dose can be improved by a factor of 4 to a factor of 100. Because of the improvement in the speed of calculating a treatment dose, the new adaptive hollow sphere method for calculating a treatment dose can be used routinely in designing a treatment plan. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 20 条
[1]   RAPID DOSE CALCULATIONS FOR STEREOTAXIC RADIOSURGERY [J].
BARDASH, M ;
AMOLS, HI ;
KOHN, S ;
MARTEL, MK ;
WUU, CS ;
SISTI, M ;
CHANG, CH .
MEDICAL PHYSICS, 1992, 19 (04) :965-970
[2]  
COLOMBO F, 1985, APPL NEUROPHYSIOL, V48, P133
[3]   CEREBRAL RADIATION SURGERY USING MOVING FIELD IRRADIATION AT A LINEAR-ACCELERATOR FACILITY [J].
HARTMANN, GH ;
SCHLEGEL, W ;
STURM, V ;
KOBER, B ;
PASTYR, O ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (06) :1185-1192
[4]   STEREOTAXIC RADIOTHERAPY TECHNIQUE FOR SMALL INTRACRANIAL LESIONS [J].
HOUDEK, PV ;
FAYOS, JV ;
VANBUREN, JM ;
GINSBERG, MS .
MEDICAL PHYSICS, 1985, 12 (04) :469-472
[5]  
ISSAC IR, 1991, MED PHYS, V18, P141
[6]   TREATMENT PLANNING FOR STEREOTAXIC RADIOSURGERY OF INTRACRANIAL LESIONS [J].
KOOY, HM ;
NEDZI, LA ;
LOEFFLER, JS ;
ALEXANDER, E ;
CHENG, CW ;
MANNARINO, EG ;
HOLUPKA, EJ ;
SIDDON, RL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :683-693
[7]   TREATMENT PLANNING OPTIMIZATION FOR MULTIPLE ARCS STEREOTAXIC RADIOSURGERY USING A LINEAR-ACCELERATOR [J].
LAM, CF ;
ZHU, JG ;
PENN, JO ;
JENRETTE, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (03) :647-657
[8]  
LUTI W, 1988, INT J RADIOL BIOL PH, V14, P373
[9]  
LUTZ W, 1985, INT J RADIAT ONCOL, V11, P1185
[10]   ALGORITHM FOR DOSIMETRY OF MULTIARC LINEAR-ACCELERATOR STEREOTAXIC RADIOSURGERY [J].
LUXTON, G ;
JOZSEF, G ;
ASTRAHAN, MA .
MEDICAL PHYSICS, 1991, 18 (06) :1211-1221