Diffusion-weighted imaging of bone marrow: current status

被引:87
作者
Baur, A [1 ]
Dietrich, O [1 ]
Reiser, M [1 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
关键词
MRI; diffusion-weighted imaging; bone marrow; neoplasms;
D O I
10.1007/s00330-003-1873-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion-weighted imaging allows for measurement of tissue microstructure and reflects the random motion of water protons. It provides a new method to study bone marrow and bone marrow alterations on the basis of altered water-proton mobility in various diseases. Different diffusion-weighted methods have proved to be capable of differentiating between benign edema and tumorous involvement of bone marrow. It is especially useful for the distinction of acute benign osteoporotic and malignant vertebral compression fractures. Diagnosis is based on the contrast to normal bone marrow. Hypo- or isointensity reflects acute benign collapse, whereas hyperintensity is indicative of the tumorous nature of a fracture. Apparent diffusion coefficients (ADC) are significantly lower in metastatic disease than in bone marrow edema. Furthermore, bone marrow cellularity can be estimated by ADC measurements. Diffusion-weighted imaging might be helpful for monitoring response to therapy in metastatic disease.
引用
收藏
页码:1699 / 1708
页数:10
相关论文
共 53 条
[41]   Diffusion tensor MR imaging of the human brain [J].
Pierpaoli, C ;
Jezzard, P ;
Basser, PJ ;
Barnett, A ;
DiChiro, G .
RADIOLOGY, 1996, 201 (03) :637-648
[42]   Diffusion-weighted MR imaging for differentiation of benign fracture edema and tumor infiltration of the vertebral body [J].
Spuentrup, E ;
Buecker, A ;
Adam, G ;
van Vaals, JJ ;
Guenther, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :351-358
[43]   Differential diagnosis of erosive osteochondrosis and bacterial spondylitis in MRI [J].
Stabler, A ;
Baur, A ;
Kruger, A ;
Weiss, M ;
Helmberger, T ;
Reiser, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (05) :421-428
[44]   SPIN DIFFUSION MEASUREMENTS: SPIN ECHOES IN THE PRESENCE OF A TIME-DEPENDENT FIELD GRADIENT [J].
STEJSKAL, EO ;
TANNER, JE .
JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (01) :288-+
[45]  
TASALY N, 2000, RADIOLOGY S, V217, P68
[46]  
Tievsky AL, 1999, AM J NEURORADIOL, V20, P1491
[47]  
TSURUDA JS, 1990, AM J NEURORADIOL, V11, P925
[48]   Magnetic resonance imaging of normal bone marrow [J].
Vande Berg, BC ;
Malghem, J ;
Lecouvet, FE ;
Maldague, B .
EUROPEAN RADIOLOGY, 1998, 8 (08) :1327-1334
[49]   MRI of bone marrow disorders [J].
Vanel, D ;
Dromain, C ;
Tardivon, A .
EUROPEAN RADIOLOGY, 2000, 10 (02) :224-229
[50]   Analysis of diffusion changes in posttraumatic bone marrow using navigator-corrected diffusion gradients [J].
Ward, R ;
Caruthers, S ;
Yablon, C ;
Blake, M ;
DiMasi, M ;
Eustace, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) :731-734