Midterm angiographic outcome of single-vessel intracoronary stent placement in diabetic versus nondiabetic patients: A matched comparative study

被引:37
作者
Lau, KW [1 ]
Ding, ZP [1 ]
Johan, A [1 ]
Lim, YL [1 ]
机构
[1] Natl Heart Ctr, Singapore 0316, Singapore
关键词
D O I
10.1016/S0002-8703(98)70195-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background It remains controversial whether diabetes is associated with an increased risk of restenosis after intracoronary stenting. Methods and Results We selected 42 diabetic patients and an equal number of nondiabetic patients with followup angiographic restudy after single-vessel stenting, matched for 4 important stent-related and angiographic variables (stent design, reference vessel size and expanded stent diameter, coronary vessel treated, and poststent residual diameter stenosis). The 2 patient groups did not differ in their baseline lesion severity and acute luminal gain. At 5-month angiographic assessment, the observed in-stent restenosis rate was significantly higher in diabetic than nondiabetic patients (40.5% vs 16.7%, P = 0.0157). It was highest in diabetic patients who received small stents <3.0 mm in diameter and intermediate in diabetic patients who received larger stent sizes (55% vs 27%, P = 0.0675). The frequency of restenosis in nondiabetic patients, however, was low; it was 18% and 15% in those who received small stents and larger stents, respectively (P = 0.7823). Conclusions Our data suggest that diabetes predisposes to on increased risk of in-stent restenosis, particularly in small vessels.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 21 条
[1]   Potential mechanisms promoting restenosis in diabetic patients [J].
Aronson, D ;
Bloomgarden, Z ;
Rayfield, EJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (03) :528-535
[2]   ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE [J].
CARROZZA, JP ;
KUNTZ, RE ;
LEVINE, MJ ;
POMERANTZ, RM ;
FISHMAN, RF ;
MANSOUR, M ;
GIBSON, CM ;
SENERCHIA, CC ;
DIVER, DJ ;
SAFIAN, RD ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :328-337
[3]   CORONARY MORPHOLOGICAL AND CLINICAL DETERMINANTS OF PROCEDURAL OUTCOME WITH ANGIOPLASTY FOR MULTIVESSEL CORONARY-DISEASE - IMPLICATIONS FOR PATIENT SELECTION [J].
ELLIS, SG ;
VANDORMAEL, MG ;
COWLEY, MJ ;
DISCIASCIO, G ;
DELIGONUL, U ;
TOPOL, EJ ;
BULLE, TM .
CIRCULATION, 1990, 82 (04) :1193-1202
[4]   RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE [J].
ELLIS, SG ;
SAVAGE, M ;
FISCHMAN, D ;
BAIM, DS ;
LEON, M ;
GOLDBERG, S ;
HIRSHFELD, JW ;
CLEMAN, MW ;
TEIRSTEIN, PS ;
WALKER, C ;
BAILEY, S ;
BUCHBINDER, M ;
TOPOL, EJ ;
SCHATZ, RA .
CIRCULATION, 1992, 86 (06) :1836-1844
[5]   SAFETY, SUCCESS, AND RESTENOSIS AFTER ELECTIVE CORONARY IMPLANTATION OF THE PALMAZ-SCHATZ STENT IN 100 PATIENTS AT A SINGLE CENTER [J].
FOLEY, JB ;
PENN, IM ;
BROWN, RIG ;
MURRAYPARSONS, N ;
WHITE, J ;
GALLIGAN, L ;
MACDONALD, C .
AMERICAN HEART JOURNAL, 1993, 125 (03) :686-694
[6]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[7]   RESTENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY (PTCA) - A REPORT FROM THE PTCA REGISTRY OF THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE [J].
HOLMES, DR ;
VLIETSTRA, RE ;
SMITH, HC ;
VETROVEC, GW ;
KENT, KM ;
COWLEY, MJ ;
FAXON, DP ;
GRUENTZIG, AR ;
KELSEY, SF ;
DETRE, KM ;
VANRADEN, MJ ;
MOCK, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (12) :C77-C81
[8]   NOVEL-APPROACH TO THE ANALYSIS OF RESTENOSIS AFTER THE USE OF 3 NEW CORONARY DEVICES [J].
KUNTZ, RE ;
SAFIAN, RD ;
LEVINE, MJ ;
REIS, GJ ;
DIVER, DJ ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1493-1499
[9]   GENERALIZED-MODEL OF RESTENOSIS AFTER CONVENTIONAL BALLOON ANGIOPLASTY, STENTING AND DIRECTIONAL ATHERECTOMY [J].
KUNTZ, RE ;
GIBSON, CM ;
NOBUYOSHI, M ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :15-25
[10]   Long-term (4- to 6-year) outcome of Palmaz-Schatz stenting: Paucity of late clinical stent-related problems [J].
Laham, RJ ;
Carrozza, JP ;
Berger, C ;
Cohen, DJ ;
Kuntz, RE ;
Baim, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (04) :820-826