Changes in root canal geometry after preparation assessed by high-resolution computed tomography

被引:267
作者
Peters, OA
Laib, A
Göhring, TN
Barbakow, F
机构
[1] Univ Zurich, Dept Prevent Dent Cariol & Periodontol, Div Cariol, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
[3] Univ Zurich, Div Endodontol, Zurich, Switzerland
关键词
D O I
10.1097/00004770-200101000-00001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Root canal morphology chanties during canal preparation, and these changes may vary depending on the technique used. Such changes have been studied in vitro by measuring cross-sections of canals before and after preparation. This current study used nondestructive high-resolution scanning tomography to assess changes in the canals' paths after preparation. A microcomputed tomography scanner (cubic resolution 34 mum) was used to analyze 18 canals in 6 extracted maxillary molars. Canals were scanned before and after preparation using either K-files, Lightspeed, or ProFile.04 rotary instruments. A special mounting device enabled precise repositioning and scanning of the specimens after preparation. Differences in surface area (DeltaA in mm(2)) and volume (DeltaV in mm(3)) of each canal before and after preparation were calculated using custom-made software. DeltaV ranged from 0.64 to 2.86, with a mean of 1.61 +/- 0.7, whereas DeltaA varied from 0.72 to 9.66, with a mean of 4.16 +/- 2.63. Mean DeltaV and DeltaA for the K-File, Profile, and Lightspeed groups were 1.28 +/- 0.57 and 2.58 +/- 1.83; 1.79 +/- 0.66 and 4.86 +/- 2.53; and 1.81 +/- 0.57 and 5.31 +/- 2.98, respectively. Canal anatomy and the effects of preparation were further analyzed using the Structure Model Index and the Transportation of Centers of Mass. Under the conditions of this study variations in canal geometry before preparation had more influence on the changes during preparation than the techniques themselves. Consequently studies comparing the effects of root canal instruments on canal anatomy should also consider details of the preoperative canal geometry.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 20 条
[1]  
ALYASSIN AM, 1994, MED PHYS, V19, P419
[2]   External and internal macromorphology in 3D-reconstructed maxillary molars using computerized X-ray microtomography [J].
Bjorndal, L ;
Carlsen, O ;
Thuesen, G ;
Darvann, T ;
Kreiborg, S .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (01) :3-9
[3]   A METHODOLOGY FOR EVALUATION OF ROOT-CANAL INSTRUMENTATION [J].
BRAMANTE, CM ;
BERBERT, A ;
BORGES, RP .
JOURNAL OF ENDODONTICS, 1987, 13 (05) :243-245
[4]  
Bryant ST, 1998, INT ENDOD J, V31, P275
[5]  
Bryant ST, 1998, INT ENDOD J, V31, P282
[6]   X-ray microtomography of bones and teeth [J].
Davis, GR ;
Wong, FSL .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 (03) :121-146
[7]   X-ray microtomography - Nondestructive three-dimensional imaging for in vitro endodontic studies [J].
Dowker, SEP ;
Davis, GR ;
Elliott, JC .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1997, 83 (04) :510-516
[8]   Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography [J].
Gambill, JM ;
Alder, M ;
delRio, CE .
JOURNAL OF ENDODONTICS, 1996, 22 (07) :369-375
[9]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[10]   A new method for the model-independent assessment of thickness in three-dimensional images [J].
Hildebrand, T ;
Ruegsegger, P .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 185 :67-75