The feasibility of maximum length sequences to reduce acquisition time of the middle latency response

被引:17
作者
Bell, SL [1 ]
Allen, R [1 ]
Lutman, ME [1 ]
机构
[1] Univ Southampton, Inst Sound & Vibrat Res, Southampton SO17 1BJ, Hants, England
关键词
D O I
10.1121/1.1340645
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Maximum length sequences (MLS) have been used to improve the signal-to-noise: ratio (SNR) of otoacoustic emissions [Thornton, J. Acoust. Sec. Am. 94, 132-136 (1993)] and the auditory brainstem response [Thornton and Slaven, Br. J. Audiol. 27, 205-210 (1993)]. By implication, a shorter recording time would be required to give equal signal-to-noise ratio (SNR). This study aimed to establish whether it is also possible to improve the SNR of the auditory-evoked potential termed the middle latency response (MLR) using maximum length sequences (MLS). Recordings of 180 s each were made using a conventional recording rate and MILS rates of 42, 89, and 185 clicks/s. Three different stimulus intensities were used in the range 30 to 70 dB nHL. The rate of 89 clicks/s was found to produce most improvement in SNR for both the N-a-P-a region of the MLR and the N-a-P-b region. This improvement in SNR using MLS implies that an MLS rate of 89 clicks/s would produce a fourfold reduction in recording time for equal SNR over conventional recording for the P-a-N-b region of the MLR at a stimulus intensity of 70 dB nHL. The latency of the Nb wave was found to reduce significantly using MLS. An MLR could not be recorded from every subject in this study, but more subjects had an identifiable response For MLS than for conventional recordings. Use of MLS to record the MLR appears to offer the potential for reduction in test time and better wave identification. (C) 2001 Acoustical Society of America.
引用
收藏
页码:1073 / 1081
页数:9
相关论文
共 25 条
[11]   EVALUATION OF THE ACTIONS OF GENERAL-ANESTHETICS IN THE HUMAN BRAIN [J].
JESSOP, J ;
JONES, JG .
GENERAL PHARMACOLOGY, 1992, 23 (06) :927-935
[12]   Brainstem auditory evoked response recorded using maximum length sequences in term neonates [J].
Jiang, ZD ;
Brosi, DM ;
Wilkinson, AR .
BIOLOGY OF THE NEONATE, 1999, 76 (04) :193-199
[13]  
JONES JG, 1989, CLIN ANAESTHESIOLOGY
[14]   BINAURAL MAXIMUM LENGTH SEQUENCE AUDITORY-EVOKED BRAIN-STEM RESPONSES IN HUMAN ADULTS [J].
LASKY, RE ;
SHI, Y ;
HECOX, KE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 93 (04) :2077-2087
[15]  
LEUNG SM, 1996, THESIS U SOUTHAMPTON
[16]  
LINAGRANADE G, 1994, AUDIOLOGY, V33, P218
[17]   Auditory evoked potential index: a quantitative measure of changes in auditory evoked potentials during general anaesthesia [J].
Mantzaridis, H ;
Kenny, GNC .
ANAESTHESIA, 1997, 52 (11) :1030-1036
[18]  
Musiek F E, 1997, J Am Acad Audiol, V8, P173
[19]   HUMAN AUDITORY EVOKED-POTENTIALS RECORDED USING MAXIMUM LENGTH SEQUENCES [J].
PICTON, TW ;
CHAMPAGNE, SC ;
KELLETT, AJC .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 84 (01) :90-100
[20]   HIGH-RATE OTOACOUSTIC EMISSIONS [J].
THORNTON, ARD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 94 (01) :132-136