Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: Initial experience

被引:198
作者
Juergens, KU
Grude, M
Maintz, D
Fallenberg, EM
Wichter, T
Heindel, W
Fischbach, R
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Munster, Dept Cardiol & Angiol, D-48149 Munster, Germany
关键词
computed tomography (CT); multi-detector row; heart; CT; MR; ventricles;
D O I
10.1148/radiol.2302030042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine left ventricular (LV) volumetric and functional parameters from retrospectively electrocardiographically gated multi-detector row computed tomography (CT) by using semiautomated analysis software and to correlate results with those of magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 30 patients (mean age, 59.2 years +/- 7.1 [SD]) known to have or suspected of having coronary artery disease, four-channel multidetector row CT was performed with standard technique, and diastolic and systolic image reconstructions were generated. With commercially available analysis software capable of semiautomated contour detection, end diastolic and end systolic LV volumes were determined from short-axis secondary CT reformations. Steady-state free-precession cine MR images were acquired in short-axis orientation within 48 hours and analyzed by using dedicated software. Bland-Altman analysis was performed to calculate limits of agreement and systematic errors between CT and MR imaging. RESULTS: Mean end diastolic (138.8 mL +/- 31.9) and end systolic (53.9 mL +/- 21.2) LV volumes as determined with CT correlated well with MR imaging measurements (142.0 mL +/- 32.5 [r = 0.93] and 54.9 mL +/- 22.8 [r = 0.94], respectively [P <.001]). LV ejection fraction (61.6% +/- 10.6 for CT vs 62.3% +/- 10.1 for MR imaging; r = 0.89) and stroke volume (84.6 mL +/- 20.9 for CT vs 86.9 mL +/- 21.5 for MR imaging; r = 0.88) also showed good correlation (P <.001). Bland-Altman analysis showed acceptable limits of agreement (+/-9.8% for ejection fraction) without systematic errors. CONCLUSION: In selected patients, semiautomated analysis software enables LV volumetric and functional analysis based on multi-detector row CT data sets, the results of which correlate well with MR imaging findings. ((C))RSNA, 2003.
引用
收藏
页码:403 / 410
页数:8
相关论文
共 18 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Boese JM, 2001, RADIOLOGY, V221, P457
[4]   MR imaging of the heart in patients after myocardial infarction: Effect of increasing intersection gap on measurements of left ventricular volume, ejection fraction, and wall thickness [J].
Cottin, Y ;
Touzery, C ;
Guy, F ;
Lalande, A ;
Ressencourt, O ;
Roy, S ;
Walker, PM ;
Louis, P ;
Brunotte, F ;
Wolf, JE .
RADIOLOGY, 1999, 213 (02) :513-520
[5]   Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography [J].
Dirksen, MS ;
Bax, JJ ;
de Roos, A ;
Jukema, JW ;
van der Geest, RJ ;
Geleijns, K ;
Boersma, E ;
van der Wall, EE ;
Lamb, HJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (10) :1157-+
[6]   Coronary artery aneurysm and type-A aortic dissection demonstrated by retrospectively ECG-gated multislice spiral CT [J].
Fallenberg, EM ;
Juergens, KU ;
Wichter, T ;
Scheld, HH ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2002, 12 (01) :201-204
[7]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[8]  
Halliburton SS, 2002, RADIOLOGY, V225, P389
[9]  
Halliburton SS, 2001, RADIOLOGY, V221, P452
[10]   Using ECG-gated multicletector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease [J].
Juergens, KU ;
Grude, M ;
Fallenberg, EM ;
Opitz, C ;
Wichter, T ;
Heindel, W ;
Fischbach, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) :1545-1550