MR imaging of the heart in patients after myocardial infarction: Effect of increasing intersection gap on measurements of left ventricular volume, ejection fraction, and wall thickness

被引:33
作者
Cottin, Y
Touzery, C
Guy, F
Lalande, A
Ressencourt, O
Roy, S
Walker, PM
Louis, P
Brunotte, F
Wolf, JE
机构
[1] Ctr Hosp Univ, Dept Cardiol, F-21034 Dijon, France
[2] Ctr Hosp Univ, Dept Magnet Resonance Imaging, F-21034 Dijon, France
关键词
heart; ejection fraction; MR; ventricles; volume; magnetic resonance (MR); cine study; volume measurement; myocardium; infarction;
D O I
10.1148/radiology.213.2.r99nv38513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the extent to which the number of planes imaged at magnetic resonance (MR) imaging could be reduced without modifying the volume and thickness of the left ventricle. MATERIALS AND METHODS: Sixty-one patients were examined after a myocardial infarction. The whole left ventricle was imaged by using 5-mm contiguous breath-hold cine MR short-axis sections with no gap (SA(ng)) (two-dimensional fast low-angle shot sequence, 9/4.8 [repetition time msec/echo time msec]). The effect of omitting in two (short-axis sections with 5-mm gap [SA(5mm)]) or two sections in three(short-axis sections with 10-mm gap [SA(10mm)]) was studied. RESULTS: In the comparison of SA(5mm) or SA(10mm) with respect to the reference SA(ng), standard Error of the estimate (SEE) for the diastolic volume did not exceed the 6.1% interobserver SEE, and the SEE for the ejection fraction remained lower than the 3% interobserver SEE. The measured wall thickness was not affected. In addition, six simple geometric models were compared with SA(ng) and yielded an SEE of 9.5%-28.1% for the diastolic volume and 3.8%-13.3% for the ejection fraction. CONCLUSION: In the study of left ventricles with heterogeneous contractility, short-axis imaging is more accurate than geometric modeling and permits wall thickness measurements when an intersection gap of 5 or 10 mm is used.
引用
收藏
页码:513 / 520
页数:8
相关论文
共 42 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   COMPARISON OF LOW-DOSE DOBUTAMINE GRADIENT-ECHO MAGNETIC-RESONANCE-IMAGING AND POSITRON EMISSION TOMOGRAPHY WITH [F-18] FLUORODEOXYGLUCOSE IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE - A FUNCTIONAL AND MORPHOLOGICAL APPROACH TO THE DETECTION OF RESIDUAL MYOCARDIAL VIABILITY [J].
BAER, FM ;
VOTH, E ;
SCHNEIDER, CA ;
THEISSEN, P ;
SCHICHA, H ;
SECHTEM, U .
CIRCULATION, 1995, 91 (04) :1006-1015
[3]   GRADIENT-ECHO MAGNETIC-RESONANCE-IMAGING DURING INCREMENTAL DOBUTAMINE INFUSION FOR THE LOCALIZATION OF CORONARY-ARTERY STENOSES [J].
BAER, FM ;
VOTH, E ;
THEISSEN, P ;
SCHICHA, H ;
SECHTEM, U .
EUROPEAN HEART JOURNAL, 1994, 15 (02) :218-225
[4]  
BAER FM, 1992, AM HEART J, V123, P636
[5]   INTERSTUDY REPRODUCIBILITY OF BIPLANE CINE NUCLEAR-MAGNETIC-RESONANCE MEASUREMENTS OF LEFT-VENTRICULAR FUNCTION [J].
BENJELLOUN, H ;
CRANNEY, GB ;
KIRK, KA ;
BLACKWELL, GG ;
LOTAN, CS ;
POHOST, GM .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (16) :1413-1420
[6]  
BLAND JM, 1986, LANCET, V13, P1294
[7]   EFFECT OF PHASIC RESPIRATION ON LEFT-VENTRICULAR DIMENSION AND PERFORMANCE IN A NORMAL POPULATION - ECHOCARDIOGRAPHIC STUDY [J].
BRENNER, JI ;
WAUGH, RA .
CIRCULATION, 1978, 57 (01) :122-127
[8]   COMPARISON OF SINGLE AND BIPLANE VENTRICULOGRAPHY FOR DETERMINATION OF LEFT-VENTRICULAR VOLUME AND EJECTION FRACTION [J].
BROGAN, WC ;
GLAMANN, DB ;
LANGE, RA ;
HILLIS, LD .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (12) :1079-1082
[9]   NONINVASIVE QUANTIFICATION OF LEFT-VENTRICULAR ROTATIONAL DEFORMATION IN NORMAL HUMANS USING MAGNETIC-RESONANCE-IMAGING MYOCARDIAL TAGGING [J].
BUCHALTER, MB ;
WEISS, JL ;
ROGERS, WJ ;
ZERHOUNI, EA ;
WEISFELDT, ML ;
BEYAR, R ;
SHAPIRO, EP .
CIRCULATION, 1990, 81 (04) :1236-1244
[10]   LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY [J].
CRANNEY, GB ;
LOTAN, CS ;
DEAN, L ;
BAXLEY, W ;
BOUCHARD, A ;
POHOST, GM .
CIRCULATION, 1990, 82 (01) :154-163