INTERSTUDY REPRODUCIBILITY OF BIPLANE CINE NUCLEAR-MAGNETIC-RESONANCE MEASUREMENTS OF LEFT-VENTRICULAR FUNCTION

被引:72
作者
BENJELLOUN, H
CRANNEY, GB
KIRK, KA
BLACKWELL, GG
LOTAN, CS
POHOST, GM
机构
[1] UNIV ALABAMA,DEPT MED,DIV CARDIOVASC DIS,BIRMINGHAM,AL 35294
[2] UNIV MOHAMMED 5,CHU AVICENNE,DEPT CARDIOL,RABAT,MOROCCO
[3] HADASSAH MED CTR,DEPT CARDIOL,JERUSALEM,ISRAEL
关键词
D O I
10.1016/0002-9149(91)90473-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cine nuclear magnetic resonance (NMR) imaging, as a noninvasive and high-resolution imaging modality, has been shown to be reliable for determining absolute left ventricular (LV) volumes and ejection fraction. A relatively new gradient echo cine NMR approach using 2 orthogonal long-axis planes (2- and 4-chamber) aligned with the true axes of the left ventricle has been previously developed and validated against radiographic biplane LV cineangiography. The aim of the present investigation was to determine the reproducibility of this more rapid cine NMR approach for the measurement of LV volumes and ejection fraction. Eighteen normal subjects underwent 2 cine NMR studies, on different days, using a 1.5-tesla clinical imaging system. Studies were analyzed on-line and blindly by 2 independent observers. Intraobserver error was also determined in a blinded manner. Mean values of measurements determined by this method in this group of normal subjects were end-diastolic volume (120 +/- 20 ml), end-systolic volume (39 +/- 9 ml) and ejection fraction (67 +/- 4%). Paired analysis of data revealed no significant bias between interstudy, interobserver or intraobserver measurements, except for interobserver end-diastolic volume, where the first observer measurements were slightly elevated (5.6 +/- 7.8 ml) compared with the second. This resulted in a small difference in ejection fraction (1.7 +/- 2.3%) between observers. The absolute variation between measurements (square root of variance components) was low for all interstudy, interobserver and intraobserver comparisons: end-diastolic volume was < +/- 6.7 ml, end-systolic volume < +/- 3.5 ml and ejection fraction < +/- 2.4%. These results demonstrate the potential of the biplane cine NMR intrinsic long-axis approach to obtain reliable and sequential measurements of LV volumes and function in subjects without segmental wall motion abnormalities, using practical acquisition and analysis times.
引用
收藏
页码:1413 / 1420
页数:8
相关论文
共 33 条
  • [1] NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE
    BUSER, PT
    AUFFERMANN, W
    HOLT, WW
    WAGNER, S
    KIRCHER, B
    WOLFE, C
    HIGGINS, CB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) : 1294 - 1300
  • [2] OBJECTIVE AND SUBJECTIVE ANALYSIS OF LEFT-VENTRICULAR ANGIOGRAMS
    CHAITMAN, BR
    DEMOTS, H
    BRISTOW, JD
    ROSCH, J
    RAHIMTOOLA, SH
    [J]. CIRCULATION, 1975, 52 (03) : 420 - 425
  • [3] REPRODUCIBILITY OF ANGIOGRAPHIC LEFT VENTRICULAR EJECTION FRACTION IN PATIENTS WITH CORONARY-ARTERY DISEASE
    COHN, PF
    LEVINE, JA
    BERGERON, GA
    GORLIN, R
    [J]. AMERICAN HEART JOURNAL, 1974, 88 (06) : 713 - 720
  • [4] LEFT-VENTRICULAR EJECTION FRACTION AS A PROGNOSTIC GUIDE IN SURGICAL TREATMENT OF CORONARY AND VALVULAR HEART-DISEASE
    COHN, PF
    GORLIN, R
    COHN, LH
    COLLINS, JJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (02) : 136 - 141
  • [5] Cranney G B, 1990, Curr Probl Cardiol, V15, P87, DOI 10.1016/0146-2806(90)90028-O
  • [6] LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY
    CRANNEY, GB
    LOTAN, CS
    DEAN, L
    BAXLEY, W
    BOUCHARD, A
    POHOST, GM
    [J]. CIRCULATION, 1990, 82 (01) : 154 - 163
  • [7] DETERMINATION OF LEFT-VENTRICULAR VOLUMES AND EJECTION FRACTION BY NUCLEAR-MAGNETIC-RESONANCE IMAGING
    DILWORTH, LR
    AISEN, AM
    MANCINI, GBJ
    LANDE, I
    BUDA, AJ
    [J]. AMERICAN HEART JOURNAL, 1987, 113 (01) : 24 - 32
  • [8] THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN
    DODGE, HT
    SANDLER, H
    BALLEW, DW
    LORD, JD
    [J]. AMERICAN HEART JOURNAL, 1960, 60 (05) : 762 - 776
  • [9] CARDIAC-FUNCTION - EVALUATION WITH FAST-ECHO MR IMAGING
    EDELMAN, RR
    THOMPSON, R
    KANTOR, H
    BRADY, TJ
    LEAVITT, M
    DINSMORE, R
    [J]. RADIOLOGY, 1987, 162 (03) : 611 - 615
  • [10] SECTIONAL AND SEGMENTAL VARIABILITY OF LEFT-VENTRICULAR FUNCTION - EXPERIMENTAL AND CLINICAL-STUDIES USING ULTRAFAST COMPUTED-TOMOGRAPHY
    FEIRING, AJ
    RUMBERGER, JA
    REITER, SJ
    COLLINS, SM
    SKORTON, DJ
    REES, M
    MARCUS, ML
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) : 415 - 425