High-pressure effects in miniature arrays of quadrupole analyzers for residual gas analysis from 10(-9) to 10(-2) Torr

被引:74
作者
Ferran, RJ
Boumsellek, S
机构
[1] Ferran Scientific, Inc., San Diego, CA 92121
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A | 1996年 / 14卷 / 03期
关键词
D O I
10.1116/1.579938
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The design, construction, and characterization of a miniature array of 16 rods forming nine quadrupole mass analyzers for residual gas analysis are presented. The novel design takes advantage of the reduction of the dimensions and hence the mean free path to broaden the dynamic range by extending the operating pressure range up to 10 mTorr at the high end while maintaining the low-end sensitivity and mass resolution. The small size, low weight, low power consumption, and low cost of this mass analyzer enable many new applications such as ia situ process control in high pressure processes. Applications which take advantage of the capability of operating the source pressure two orders of magnitude higher than conventional devices such as high-pressure contaminant monitoring are discussed. Data on high-pressure effects on the ionizer lifetime in various atmospheres and nonlinearities of the signal are presented and correlated with theoretical analysis. Ray tracing simulations and Monte Carlo statistical calculations are used to provide an understanding of the sensitivity reduction at pressures-substantially higher than 10 m Torr. These calculations take into account the ion charge density in the source and the dissociation, charge exchange, and energy loss by the ions when colliding with residual molecules along the length of the rods. (C) 1996 American Vacuum Society.
引用
收藏
页码:1258 / 1265
页数:8
相关论文
共 11 条
[1]   INCREASED RESPONSE OF THE REVERSAL ELECTRON-ATTACHMENT DETECTOR AND MODELING OF ION SPACE-CHARGE EFFECTS [J].
BOUMSELLEK, S ;
CHUTJIAN, A .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2096-2100
[2]   NONLINEARITIES IN SENSITIVITY OF QUADRUPOLE PARTIAL-PRESSURE ANALYZERS OPERATING AT HIGHER GAS-PRESSURES [J].
COWEN, MC ;
ALLISON, W ;
BATEY, JH .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1994, 12 (01) :228-234
[3]  
DAVIES L, UNPUB
[4]  
Dawson PH., 1995, QUADRUPOLE MASS SPEC, DOI 10.1016/
[5]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[6]  
FERRAN RJ, 1995, Patent No. 5401962
[7]  
Herrmannsfeldt W.B, 1988, EGUN: An Electron Optics and Gun Design Program
[8]   DAS ELEKTRISCHE MASSENFILTER ALS MASSENSPEKTROMETER UND ISOTOPENTRENNER [J].
PAUL, W ;
REINHARD, HP ;
VONZAHN, U .
ZEITSCHRIFT FUR PHYSIK, 1958, 152 (02) :143-182
[9]   MONTE-CARLO INVESTIGATIONS OF MOTION OF GASEOUS IONS IN ELECTROSTATIC FIELDS [J].
SKULLERUD, HR .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1973, 6 (04) :728-742
[10]   MICROMACHINED ARRAY OF ELECTROSTATIC ENERGY ANALYZERS FOR CHARGED-PARTICLES [J].
STALDER, RE ;
BOUMSELLEK, S ;
VANZANDT, TR ;
KENNY, TW ;
HECHT, MH ;
GRUNTHANER, FE .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1994, 12 (04) :2554-2558