The present study deals with a comprehensive thermodynamic modeling of a combined heat and power (CHP) system in a paper mill, which provides 50 MW of electric power and 100 ton h(-1) saturated steam at 13 bars. This CHP plant is composed of air compressor, combustion chamber (CC), Air Preheater, Gas Turbine (GT) and a Heat Recovery Heat Exchanger. The design parameters of this cycle are compressor pressure ratio (rAC), compressor isentropic efficiency (?AC), GT isentropic efficiency (GT), CC inlet temperature (T3), and turbine inlet temperature (T4). In the multi-objective optimization three objective functions, including CHP exergy efficiency, total cost rate of the system products, and CO2 emission of the whole plant, are considered. The exergoenvironmental objective function is minimized whereas power plant exergy efficiency is maximized using a Genetic algorithm. To have a good insight into this study, a sensitivity analysis of the results to the interest rate as well as fuel cost is performed. The results show that at the lower exergetic efficiency, in which the weight of exergoenvironmental objective is higher, the sensitivity of the optimal solutions to the fuel cost is much higher than the location of the Pareto Frontier with the lower weight of exergoenvironmental objective. In addition, with increasing exergy efficiency, the purchase cost of equipment in the plant is increased as the cost rate of the plant increases. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:46 / 63
页数:18
相关论文
共 32 条
[1]  
AHMADI P, 2006, THESIS POWER WATER U
[2]   Exergy analysis of a 420 MW combined cycle power plant [J].
Ameri, M. ;
Ahmadi, P. ;
Khanmohammadi, S. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (02) :175-183
[3]   The study of ambient temperature effects on exergy losses of a heat Recovery Steam Generator [J].
Ameri, Mohammad ;
Ahmadi, Pourya .
CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, :55-+
[4]   Energy, exergy and exergoeconomic analysis of a steam power plant: A case study [J].
Ameri, Mohammad ;
Ahmadi, Pouria ;
Hamidi, Armita .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (05) :499-512
[5]  
[Anonymous], 2007, 3LSEVIER SCI
[6]  
[Anonymous], 2001, INT J ENERGY
[7]  
[Anonymous], 1994, EVOL COMPUT
[8]   Thermo-economic-environmental multiobjective optimization of a gas turbine power plant with preheater using evolutionary algorithm [J].
Avval, H. Barzegar ;
Ahmadi, P. ;
Ghaffarizadeh, A. R. ;
Saidi, M. H. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2011, 35 (05) :389-403
[9]   Energetic and exergetic performance evaluation of a combined heat and power system with the micro gas turbine (MGTCHP) [J].
Balli, Ozgur ;
Aras, Haydar .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (14) :1425-1440
[10]  
Bejan A, 1996, THERMAL DESIGN OPTIM