PET/MR images acquired with a compact MR-compatiable PET detector in a 7-T magnet

被引:120
作者
Judenhofer, Martin S.
Catana, Ciprian
Swann, Brian K.
Siegel, Stefan B.
Jung, Wulf-Ingo
Nutt, Robert E.
Cherry, Simon R.
Claussen, Claus D.
Pichler, Bernd J.
机构
[1] Univ Tubingen, Lab Preclin Imaging & Imaging Technol, Clin Radiol, D-72076 Tubingen, Germany
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[3] Siemens Preclin Solut, Knoxville, TN USA
[4] Bruker BioSpin MRI, Ettlingen, Germany
关键词
D O I
10.1148/radiol.2443061756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively use compact avalanche photodiodes instead of photomultiplier tubes to integrate a positron emission tomographic (PET) detector and a 7-T magnetic resonance (MR) imager. Materials and Methods: All animal experiments were performed in accordance with the University of Tubingen guidelines and the German law for the protection of animals. A compact lutetium oxyorthosilicate-avalanche photodiode PET detector was built and optimized to operate within a 7-T MR imager. The detector performance was investigated both outside and inside the magnet, and MR, image quality was evaluated with and without the PET detector. Two PET detectors were set up opposite each other and operated in coincidence to acquire PET images in the step-and-shoot mode in a mouse head specimen after injection of fluorine 18 fluorodeoxyglucose. Results: The performance of the PET detector when operated inside the magnet during MR image acquisition showed little degradation in energy resolution (increase from 14.6% to 15.9%). The PET detector did not influence MR imaging. The fused PET and MR images showed an anatomic match and no degradation of image quality. Conclusion: Simultaneous PET and MR imaging with a 7-T system was deemed feasible.
引用
收藏
页码:807 / 814
页数:8
相关论文
共 24 条
[1]   Accuracy of whole-body dual-modality fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: Comparison with CT and PET [J].
Antoch, G ;
Saoudi, N ;
Kuehl, H ;
Dahmen, G ;
Mueller, SP ;
Beyer, T ;
Bockisch, A ;
Debatin, JF ;
Freudenberg, LS .
JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (21) :4357-4368
[2]   Timing performance of Hi-Rez detector for time-of-flight (TOF) PET [J].
Aykac, Mehmet ;
Bauer, Florian ;
Williams, Charles W. ;
Loope, Michael ;
Schmand, Matthias .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :1084-1089
[3]  
Beyer T, 2004, J NUCL MED, V45, p25S
[4]  
CATANA C, 2006, MOL IMAGING BIOL, P82
[5]   Design of field-cycled magnetic resonance systems for small animal imaging [J].
Gilbert, K. M. ;
Handler, W. B. ;
Scholl, T. J. ;
Odegaard, J. W. ;
Chronik, B. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2825-2841
[6]   APD performance in light sharing PET applications [J].
Grazioso, R ;
Aykac, M ;
Casey, ME ;
Givens, G ;
Schmand, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) :1413-1416
[7]   Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors [J].
Judenhofer, MS ;
Pichler, BJ ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (01) :29-44
[8]   High resolution GSO block detectors using PMT-Quadrant-Sharing design for small animal PET [J].
Kim, S ;
Wong, WH ;
Xie, SP ;
Ramirez, R ;
Liu, YQ ;
Li, HD ;
Xing, T ;
Wang, Y ;
Uribe, J ;
Baghaei, H ;
Zhang, YX .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :40-43
[9]   Initial results from the Sherbrooke avalanche photodiode positron tomograph [J].
Lecomte, R ;
Cadorette, J ;
Rodrigue, S ;
Lapointe, D ;
Rouleau, D ;
Bentourkia, M ;
Yao, R ;
Msaki, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1952-1957
[10]  
LUCAS A, 2005, MOL IMAGING, P266