Ultrafast limited-angle-type x-ray tomography

被引:34
作者
Bieberle, M. [1 ]
Fischer, F.
Schleicher, E.
Hampel, U.
Koch, D.
Aktay, K. S. D. C.
Menz, H.-J.
Mayer, H.-G.
机构
[1] Forschungszentrum Dresden, Inst Safety Res, D-01314 Dresden, Germany
[2] Univ Stuttgart, Inst Nucl Technol & Engn Syst, D-70569 Stuttgart, Germany
[3] KE Technol GmbH, D-70569 Stuttgart, Germany
关键词
D O I
10.1063/1.2787879
中图分类号
O59 [应用物理学];
学科分类号
摘要
The authors present an ultrafast electron beam x-ray computed tomography technique usable for imaging of fast processes, such as multiphase flows or moving parts in technical or biological objects. The setup consists of an electron beam unit with fast deflection capability and an ultrafast multielement x-ray detector and achieves 10 000 frames/s image rate. Since full sampling of the Radon space requires an angular overlap of source path and detector which strongly decreases axial resolution, the authors devised a limited-angle-type tomography. As a demonstration they visualized the movement of particles and gas bubbles rising in a stagnant liquid. (c) 2007 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 14 条
[1]  
[Anonymous], 1988, PRINCIPLES COMPUTERI
[2]   Evaluation of a limited angle scanned electron beam x-ray CT approach for two-phase pipe flows [J].
Bieberle, M. ;
Hampel, U. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (08) :2057-2065
[3]   CARDIAC COMPUTED-TOMOGRAPHY [J].
BOYD, DP ;
LIPTON, MJ .
PROCEEDINGS OF THE IEEE, 1983, 71 (03) :298-307
[4]   ALGEBRAIC RECONSTRUCTION TECHNIQUES (ART) FOR 3-DIMENSIONAL ELECTRON MICROSCOPY AND X-RAY PHOTOGRAPHY [J].
GORDON, R ;
BENDER, R ;
HERMAN, GT .
JOURNAL OF THEORETICAL BIOLOGY, 1970, 29 (03) :471-&
[5]   Experimental ultra fast X-ray computed tomography with a linearly scanned electron beam source [J].
Hampel, U ;
Speck, M ;
Koch, D ;
Menz, HJ ;
Mayer, HG ;
Fietz, J ;
Hoppe, D ;
Schleicher, E ;
Zippe, C ;
Prasser, HM .
FLOW MEASUREMENT AND INSTRUMENTATION, 2005, 16 (2-3) :65-72
[6]   Development of ultra-fast X-ray computed tomography scanner system [J].
Hori, K ;
Fujimoto, T ;
Kawanishi, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) :2089-2094
[7]   A dual sensor flow imaging tomographic system [J].
Johansen, GA ;
Froystein, T ;
Hjertaker, BT ;
Olsen, O .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (03) :297-307
[8]  
KANTZAS A, 1994, AICHE J, V40, P1254, DOI 10.1002/aic.690400716
[9]   A GAMMA-RAY TOMOGRAPHIC SCANNER FOR IMAGING VOIDAGE DISTRIBUTION IN 2-PHASE FLOW SYSTEMS [J].
KUMAR, SB ;
MOSLEMIAN, D ;
DUDUKOVIC, MP .
FLOW MEASUREMENT AND INSTRUMENTATION, 1995, 6 (01) :61-73
[10]  
Misawa M., 2003, Kerntechnik, V68, P85