Smoothing intensity-modulated beam profiles to improve the efficiency of delivery

被引:63
作者
Spirou, SV [1 ]
Fournier-Bidoz, N [1 ]
Yang, J [1 ]
Chui, CS [1 ]
Ling, CC [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
intensity-modulated radiation therapy; optimization; inverse planning; smoothing; filtering; Savitzky-Golay;
D O I
10.1118/1.1406522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intensity-modulated beam profiles are generated by an inverse planning or optimization algorithm, a process that, being computationally complex and intensive, is inherently susceptible to noise and numerical artifacts. These artifacts make delivery of the beams more difficult, oftentimes for little, if any, observable improvement in the dose distributions. In this work we examine two approaches for smoothing the beam profiles. The first approach is to smooth the beam profiles subsequent to each iteration in the optimization process (method A). The second approach is to include a term within the objective function that specifies the smoothness of the profiles as an optimization criterion (method B). The two methods were applied to a phantom study as well as three clinical sites: paraspinal, nasopharynx, and prostate. For the paraspinal and nasopharynx cases, which have critical organs with low tolerance doses in close proximity, method B produced sharper dose gradients, better target dose homogeneity, and more critical organ sparing. In the less demanding prostate case, the two methods give similar results. In addition, method B is more efficient during optimization, requiring fewer iterations, but less efficient during DMLC delivery, requiring a longer beam-on time. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2105 / 2112
页数:8
相关论文
共 23 条
[1]   Intensity modulated photon beams subject to a minimal surface smoothing constraint [J].
Alber, M ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :N49-N52
[2]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[3]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[4]   The use of compensators to optimise the three dimensional dose distribution in radiotherapy of the intact breast [J].
Carruthers, LJ ;
Redpath, AT ;
Kunkler, IH .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :291-300
[5]   Reduction of computational dimensionality in inverse radiotherapy planning using sparse matrix operations [J].
Cho, PS ;
Phillips, MH .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :N117-N125
[6]   A GENERALIZED PENCIL BEAM ALGORITHM FOR OPTIMIZATION OF RADIATION-THERAPY [J].
GUSTAFSSON, A ;
LIND, BK ;
BRAHME, A .
MEDICAL PHYSICS, 1994, 21 (03) :343-357
[7]  
Happersett L., 2000, International Journal of Radiation Oncology Biology Physics, V48, P351, DOI 10.1016/S0360-3016(00)80509-X
[8]   Intensity-modulated tangential beam irradiation of the intact breast [J].
Hong, L ;
Hunt, M ;
Chui, C ;
Spirou, S ;
Forster, K ;
Lee, H ;
Yahalom, J ;
Kutcher, GJ ;
McCormick, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1155-1164
[9]   Treatment planning and delivery of intensity-modulated radiation therapy for primary nasopharynx cancer [J].
Hunt, MA ;
Zelefsky, MJ ;
Wolden, S ;
Chui, CS ;
LoSasso, T ;
Rosenzweig, K ;
Chong, L ;
Spirou, SV ;
Fromme, L ;
Lumley, M ;
Amols, HA ;
Ling, CL ;
Leibel, SA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :623-632
[10]   On compensator design for photon beam intensity-modulated conformal therapy [J].
Jiang, SB ;
Ayyangar, KM .
MEDICAL PHYSICS, 1998, 25 (05) :668-675