High-throughput nanoliter sample introduction microfluidic chip-based flow injection analysis system with gravity-driven flows

被引:130
作者
Du, WB [1 ]
Fang, Q [1 ]
He, QH [1 ]
Fang, ZL [1 ]
机构
[1] Zhejiang Univ, Inst Microanalyt Syst, Hangzhou 310027, Peoples R China
关键词
D O I
10.1021/ac048675y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a simple, robust, and automated microfluidic chip-based FIA system with gravity-driven flows and liquid-core waveguide (LCW) spectrometric detection was developed. The high-throughput sample introduction system was composed of a capillary sampling probe and an array of horizontally positioned microsample vials with a slot fabricated on the bottom of each vial. FI sample loading and injection were performed by linearly moving the array of vials filled alternately with 50-muL samples and carrier, allowing the probe inlet to enter the solutions in the vials through the slots sequentially and the sample and carrier solution to be introduced into the chip driven by gravity. The performance of the system was demonstrated using the complexation of o-phenanthroline with Fe(II) as a model reaction. A 20-mm-long Teflon AF 2400 capillary (50-mum i.d., 375-mum o.d.) was connected to the chip to function as a LCW detection flow cell with a cell volume of 40 nL and effective path length of 1.7 cm. Linear absorbance response was obtained in the range of 1.0-100 muM Fe(II) (r(2) = 0.9967), and a good reproducibility of 0.6% RSD (n = 18) was achieved. The sensitivity was comparable with that obtained using conventional FIA systems, which typically consume 10 000-fold more sample. The highest sampling throughput of 1000 h(-1) was obtained by using injection times of 0.08 and 3.4 s for sample and carrier solution, respectively, with a sample consumption of only 0.6 nL for each cycle.
引用
收藏
页码:1330 / 1337
页数:8
相关论文
共 35 条
[1]  
BABA Y, 2002, NETHERLANDS, P371
[2]   Microstructure for efficient continuous flow mixing [J].
Bessoth, FG ;
deMello, AJ ;
Manz, A .
ANALYTICAL COMMUNICATIONS, 1999, 36 (06) :213-215
[3]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[4]  
CHEN H, 2002, MICRO TOTAL ANAL SYS
[5]   Light at the end of the tunnel: recent analytical applications of liquid-core waveguides [J].
Dallas, T ;
Dasgupta, PK .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (05) :385-392
[6]   DEVELOPMENT OF A MICRO FLOW-INJECTION MANIFOLD FOR THE DETERMINATION OF ORTHOPHOSPHATE [J].
DAYKIN, RNC ;
HASWELL, SJ .
ANALYTICA CHIMICA ACTA, 1995, 313 (03) :155-159
[7]   Generation of gradients having complex shapes using microfluidic networks [J].
Dertinger, SKW ;
Chiu, DT ;
Jeon, NL ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1240-1246
[8]   Further studies into the development of a micro-FIA (μFIA) system based on electroosmotic flow for the determination of phosphate as orthophosphate [J].
Doku, GN ;
Haswell, SJ .
ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) :1-13
[9]  
Du WB, 2004, CHEM J CHINESE U, V25, P610
[10]  
Fang Q, 2004, CHEM J CHINESE U, V25, P1442