Treatment of gastric leaks with coated self-expanding stents after sleeve gastrectomy

被引:131
作者
Serra, Carlos [1 ]
Baltasar, Aniceto [1 ]
Andreo, Luis [1 ]
Perez, Nieves [1 ]
Bou, Rafael [1 ]
Bengochea, Marcelo [1 ]
Chisbert, Juan Jose [1 ]
机构
[1] Hosp Virgen Los Lirios, Serv Cirugia Gen, Alicante 03804, Spain
关键词
gastric leaks; morbid obesity; bariatric surgery; sleeve gastrectomy; coated stents;
D O I
10.1007/s11695-007-9161-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Duodenal switch (DS) is one of the most effective techniques for the treatment of morbid obesity and its co-morbidities, with mortality rate < 1%, but with 9.4% morbidity rates (6.5% due to leaks). In our experience, leaks of the staple-line after sleeve gastrectomy (SG) are the most frequent sites of fistula formation and conservative treatment usually takes a long time. We present our experience in the treatment of gastric leaks with coated self-expandable stents (CSES). Methods: 6 patients had gastric leaks at the gastroesophageal (GE) junction after SG or DS. One patient had a symptomatic gastro-bronchial fistula. Stents were placed by the interventional radiologist under fluoroscopic control and removed endoscopically. In one case, we used an uncoated Wallstent. In two patients, percutaneous microcoil embolization of the fistula was added. Results: The patient treated with the Wallstent required a total gastrectomy 6 months after placement of the uncovered stent. In the other 5 patients, coated stents were successfully removed and the gastric leaks completely sealed. Conclusions: CSES are proposed as an alternative therapeutic option for the management of GE junction leaks in bariatric surgery with good results in terms of morbidity and survival.
引用
收藏
页码:866 / 872
页数:7
相关论文
共 34 条
[21]   Treatment of gastro-jejunal leakage and fistulization after gastric bypass with coated self-expanding stents [J].
Kriwanek, Stephan ;
Ott, Nada ;
Ali-Abdullah, Sirwan ;
Pulgram, Thomas ;
Tscherney, Robert ;
Reiter, Markus ;
Roka, Rudolf .
OBESITY SURGERY, 2006, 16 (12) :1669-1674
[22]   Management of postoperative esophageal leaks with the polyflex self-expanding covered plastic stent [J].
Langer, FB ;
Wenzl, E ;
Prager, G ;
Salat, A ;
Miholic, J ;
Mang, T ;
Zacherl, J .
ANNALS OF THORACIC SURGERY, 2005, 79 (02) :398-404
[23]   Procedure incidence and in-hospital complication rates of bariatric surgery in the United States [J].
Livingston, EH .
AMERICAN JOURNAL OF SURGERY, 2004, 188 (02) :105-110
[24]  
Marshall JS, 2003, ARCH SURG-CHICAGO, V138, P520, DOI 10.1001/archsurg.138.5.520
[25]   GASTRIC BYPASS [J].
MASON, EE ;
ITO, C .
ANNALS OF SURGERY, 1969, 170 (03) :329-&
[26]   OPTIMIZING RESULTS OF GASTRIC BYPASS [J].
MASON, EE ;
PRINTEN, KJ ;
HARTFORD, CE ;
BOYD, WC .
ANNALS OF SURGERY, 1975, 182 (04) :405-414
[27]   Endoscopic management of gastrocutaneous fistula after bariatric surgery by using a fibrin sealant [J].
Papavramidis, ST ;
Eleftheriadis, EE ;
Papavramidis, TS ;
Kotzampassi, KE ;
Gamvros, OG .
GASTROINTESTINAL ENDOSCOPY, 2004, 59 (02) :296-300
[28]   Complications after Laparoscopic gastric bypass - A review of 3464 cases [J].
Podnos, YD ;
Jimenez, JC ;
Wilson, SE ;
Stevens, CM ;
Nguyen, NT .
ARCHIVES OF SURGERY, 2003, 138 (09) :957-961
[29]  
Salinas Alberto, 2006, Surg Obes Relat Dis, V2, P570, DOI 10.1016/j.soard.2006.08.007
[30]   Endoscopic treatment of thoracic esophageal anastomotic leaks by using silicone-covered, self-expanding polyester stents [J].
Schubert, D ;
Scheidbach, H ;
Kuhn, R ;
Wex, C ;
Weiss, G ;
Eder, F ;
Lippert, H ;
Pross, M .
GASTROINTESTINAL ENDOSCOPY, 2005, 61 (07) :891-896