Multidimensional chromatography coupled to mass spectrometry in analysing complex proteomics samples

被引:68
作者
Horvatovich, Peter [1 ]
Hoekman, Berend [1 ]
Govorukhina, Natalia [1 ]
Bischoff, Rainer [1 ]
机构
[1] Univ Groningen, Dept Pharm, NL-9713 AV Groningen, Netherlands
关键词
Bioinformatics; Differential Analysis; LCn-MS; Mass Spectrometry; Multidimensional Separation; Proteomics; 2-DIMENSIONAL LIQUID-CHROMATOGRAPHY; OPEN-SOURCE SOFTWARE; REVERSED-PHASE HPLC; QUANTITATIVE SHOTGUN PROTEOMICS; PEPTIDE RETENTION PREDICTION; HUMAN SERUM-PROTEINS; LC-MS DATA; ABSOLUTE QUANTIFICATION; BIOMARKER DISCOVERY; PEAK-CAPACITY;
D O I
10.1002/jssc.201000050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multidimensional chromatography coupled to mass spectrometry (LCn-MS) provides more separation power and an extended measured dynamic concentration range to analyse complex proteomics samples than one dimensional liquid chromatography coupled to mass spectrometry (1D-LC-MS). This review gives an overview of the most important aspects of LCn-MS with respect to optimizing peak capacity and evaluate orthogonality. We review recent developments in LCn-MS to analyse proteomics samples from the analyst point of view and give an overview over methods and future developments to process LCn-MS data for comprehensive differential protein expression profiling. Examples from our research, such as combining protein fractionation using high temperature reverse phase (RP) columns followed by analysis of the trypsin-digested fractions by RP LC-MS, serve to highlight possibilities and shortcomings of present-day approaches. Other LCn-MS systems that have been used to analyse highly complex shotgun proteomic samples, such as the combination of RP columns using low and high pH eluents or the combination of hydrophilic interaction liquid chromatography (HILIC) with RP-MS is discussed in detail.
引用
收藏
页码:1421 / 1437
页数:17
相关论文
共 148 条
[1]   Poly(ethylene glycol)-Based Stable Isotope Labeling Reagents for the Quantitative Analysis of Low Molecular Weight Metabolites by LC-MS [J].
Abello, Nicolas ;
Geurink, Paul P. ;
van der Toorn, Marco ;
van Oosterhout, Antoon J. M. ;
Lugtenburg, Johan ;
van der Marel, Gijs A. ;
Kerstjens, Huib A. M. ;
Postma, Dirkje S. ;
Overkleeft, Hermen S. ;
Bischoff, Rainer .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9171-9180
[2]   Comparative LC-MS: A landscape of peaks and valleys [J].
America, Antoine H. P. ;
Cordewener, Jan H. G. .
PROTEOMICS, 2008, 8 (04) :731-749
[3]   Hydrophilic interaction liquid chromatography (HILIC) in proteomics [J].
Boersema, Paul J. ;
Mohammed, Shabaz ;
Heck, Albert J. R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) :151-159
[4]   Evaluation and optimization of ZIC-HILIC-RP as an alternative MudPIT strategy [J].
Boersema, Paul J. ;
Divecha, Nullin ;
Heck, Albert J. R. ;
Mohammed, Shabaz .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (03) :937-946
[5]   Biomarker Discovery in Low-Grade Breast Cancer Using Isobaric Stable Isotope Tags and Two-Dimensional Liquid Chromatography-Tandem Mass Spectrometry (iTRAQ-2DLC-MS/MS) Based Quantitative Proteomic Analysis [J].
Bouchal, Pavel ;
Roumeliotis, Theodoros ;
Hrstka, Roman ;
Nenutil, Rudolf ;
Vojtesek, Borivoj ;
Garbis, Spiros D. .
JOURNAL OF PROTEOME RESEARCH, 2009, 8 (01) :362-373
[6]   The APEX Quantitative Proteomics Tool: Generating protein quantitation estimates from LC-MS/MS proteomics results [J].
Braisted, John C. ;
Kuntumalla, Srilatha ;
Vogel, Christine ;
Marcotte, Edward M. ;
Rodrigues, Alan R. ;
Wang, Rong ;
Huang, Shih-Ting ;
Ferlanti, Erik S. ;
Saeed, Alexander I. ;
Fleischmann, Robert D. ;
Peterson, Scott N. ;
Pieper, Rembert .
BMC BIOINFORMATICS, 2008, 9 (1)
[7]   Isotope dilution strategies for absolute quantitative proteomics [J].
Brun, Virginie ;
Masselon, Christophe ;
Garin, Jerome ;
Dupuis, Alain .
JOURNAL OF PROTEOMICS, 2009, 72 (05) :740-749
[8]   Absolute Protein Quantification by LC/MSE for Global Analysis of Salicylic Acid-induced Plant Protein Secretion Responses [J].
Cheng, Fang-yi ;
Blackburn, Kevin ;
Lin, Yu-min ;
Goshe, Michael B. ;
Williamson, John D. .
JOURNAL OF PROTEOME RESEARCH, 2009, 8 (01) :82-93
[9]   Optimized time alignment algorithm for LC-MS data: Correlation optimized warping using component detection algorithm-selected mass chromatograms [J].
Christin, Christin ;
Smilde, Age K. ;
Hoefsloot, Huub C. J. ;
Suits, Frank ;
Bischoff, Rainer ;
Horvatovich, Peter L. .
ANALYTICAL CHEMISTRY, 2008, 80 (18) :7012-7021
[10]  
Cohen S.A., 2008, MULTIDIMENSIONAL LIQ