Magnetomechanical detection of the specific activities of endonucleases by cantilevers

被引:13
作者
Weizmann, Y [1 ]
Elnathan, R [1 ]
Lioubashevski, O [1 ]
Willner, I [1 ]
机构
[1] Hebrew Univ Jerusalem, Inst Chem, IL-91904 Jerusalem, Israel
关键词
D O I
10.1021/nl050204j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Thiolated nucleic acids 1 or 2 are immobilized on Au-coated cantilevers and hybridized with the complementary nucleic acids 1a or 2a associated with magnetic particles. The duplexes 1/1a or 2/2a include specific sequences for the scission by Apa I or Mse I, respectively. The cantilevers positioned in a flow cell are subjected to an external magnetic field, leading to the deflection of the cantilevers. Upon the specific scission of the DNA duplexes by Apa 1 or Mse 1, the magnetic particles are disconnected from the cantilevers leading to their retraction to the rest position. The deflection/retraction of the cantilevers are followed by a conventional atomic force microscope optical detection system.
引用
收藏
页码:741 / 744
页数:4
相关论文
共 24 条
[1]   Electrochemical and quartz crystal microbalance detection of the cholera toxin employing horseradish peroxidase and GM1-functionalized liposomes [J].
Alfonta, L ;
Willner, I ;
Throckmorton, DJ ;
Singh, AK .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5287-5295
[2]   Label-free protein assay based on a nanomechanical cantilever array [J].
Arntz, Y ;
Seelig, JD ;
Lang, HP ;
Zhang, J ;
Hunziker, P ;
Ramseyer, JP ;
Meyer, E ;
Hegner, M ;
Gerber, C .
NANOTECHNOLOGY, 2003, 14 (01) :86-90
[3]   Biosensor based on force microscope technology [J].
Baselt, DR ;
Lee, GU ;
Colton, RJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02) :789-793
[4]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[5]   Electroanalytical and bioelectroanalytical systems based on metal and semiconductor nanoparticles [J].
Katz, E ;
Willner, I ;
Wang, J .
ELECTROANALYSIS, 2004, 16 (1-2) :19-44
[6]  
Lahav M, 2001, ANGEW CHEM INT EDIT, V40, P4095, DOI 10.1002/1521-3773(20011105)40:21<4095::AID-ANIE4095>3.0.CO
[7]  
2-9
[8]   Cantilever transducers as a platform for chemical and biological sensors [J].
Lavrik, NV ;
Sepaniak, MJ ;
Datskos, PG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (07) :2229-2253
[9]   Self-assembled double-stranded DNA (dsDNA) microarrays for protein:dsDNA screening using atomic force microscopy [J].
O'Brien, JC ;
Stickney, JT ;
Porter, MD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (20) :5004-5005
[10]   Dendritic amplification of DNA analysis by oligonucleotide-functionalized Au-nanoparticles [J].
Patolsky, F ;
Ranjit, KT ;
Lichtenstein, A ;
Willner, I .
CHEMICAL COMMUNICATIONS, 2000, (12) :1025-1026