Label-free protein assay based on a nanomechanical cantilever array

被引:315
作者
Arntz, Y
Seelig, JD
Lang, HP
Zhang, J
Hunziker, P
Ramseyer, JP
Meyer, E
Hegner, M
Gerber, C
机构
[1] Univ Basel, Natl Competence Ctr Res Nanosci, Inst Phys, CH-4056 Basel, Switzerland
[2] IBM Corp, Zurich Res Lab, CH-8803 Ruschlikon, Switzerland
关键词
D O I
10.1088/0957-4484/14/1/319
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We demonstrate continuous label-free detection of two cardiac biomarker proteins (creatin kinase and myoglobin) using an array of microfabricated cantilevers functionalized with covalently anchored anti-creatin kinase and anti-myoglobin antibodies. This method allows biomarker proteins to be detected via measurement of surface stress generated by antigen-antibody molecular recognition. Reference cantilevers are used to eliminate thermal drifts, undesired chemical reactions and turbulences from injections of liquids by calculating differential deflection signals with respect to sensor cantilevers. The sensitivity achieved for myoglobin detection is below 20 mug ml(-1). Both myoglobin and creatin kinase could be detected independently using cantilevers functionalized with the corresponding antibodies, in unspecitic protein background. This approach permits the use of up to seven different antigen-antibody reactions simultaneously, including an additional thermomechanical and chemical in situ reference. Applications lie in the field of early and rapid diagnosis of acute myocardial infarction.
引用
收藏
页码:86 / 90
页数:5
相关论文
共 17 条
  • [1] Cardiac-specific troponin I levels to predict the risk of mortality in patients with acute coronary syndromes
    Antman, EM
    Tanasijevic, MJ
    Thompson, B
    Schactman, M
    McCabe, CH
    Cannon, CP
    Fischer, GA
    Fung, AY
    Thompson, C
    Wybenga, D
    Braunwald, E
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (18) : 1342 - 1349
  • [2] Validation of antibody-based recognition by piezoelectric transducers through electroacoustic admittance analysis
    Bizet, K
    Gabrielli, C
    Perrot, H
    Therasse, J
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) : 259 - 269
  • [3] Feasibility and reliability of rapid diagnosis of myocardial infarction
    Engel, G
    Rockson, SG
    [J]. AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2001, 322 (06) : 339 - 344
  • [4] Translating biomolecular recognition into nanomechanics
    Fritz, J
    Baller, MK
    Lang, HP
    Rothuizen, H
    Vettiger, P
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    Gimzewski, JK
    [J]. SCIENCE, 2000, 288 (5464) : 316 - 318
  • [5] Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor
    Grogan, C
    Raiteri, R
    O'Connor, GM
    Glynn, TJ
    Cunningham, V
    Kane, M
    Charlton, M
    Leech, D
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) : 201 - 207
  • [6] Cardiac biomarkers for rapid evaluation of chest pain
    Hamm, CW
    [J]. CIRCULATION, 2001, 104 (13) : 1454 - 1456
  • [7] Cardiac biomarkers in the new millennium
    Herzog, CA
    Apple, FS
    [J]. SEMINARS IN DIALYSIS, 2001, 14 (05) : 322 - 323
  • [8] Nanomechanics from atomic resolution to molecular recognition based on atomic force microscopy technology
    Lang, HP
    Hegner, M
    Meyer, E
    Gerber, C
    [J]. NANOTECHNOLOGY, 2002, 13 (05) : R29 - R36
  • [9] Highly parallel data storage system based on scanning probe arrays
    Lutwyche, MI
    Despont, M
    Drechsler, U
    Dürig, U
    Häberle, W
    Rothuizen, H
    Stutz, R
    Widmer, R
    Binnig, GK
    Vettiger, P
    [J]. APPLIED PHYSICS LETTERS, 2000, 77 (20) : 3299 - 3301
  • [10] Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array
    McKendry, R
    Zhang, JY
    Arntz, Y
    Strunz, T
    Hegner, M
    Lang, HP
    Baller, MK
    Certa, U
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (15) : 9783 - 9788