This letter discusses an alternative storage approach to conventional magnetic data storage. The approach uses a 32x32 array of scanning probe microscopes working in parallel to read and write data as small indentations in a polymer storage medium. The results have densities of 100-200 Gbit/in.(2). At such densities, it is shown that well over half the array works, and at lower densities more than 80% of levers are working. (C) 2000 American Institute of Physics. [S0003-6951(00)05246-3].
引用
收藏
页码:3299 / 3301
页数:3
相关论文
共 8 条
  • [1] Ultrahigh-density atomic force microscopy data storage with erase capability
    Binnig, G
    Despont, M
    Drechsler, U
    Häberle, W
    Lutwyche, M
    Vettiger, P
    Mamin, HJ
    Chui, BW
    Kenny, TW
    [J]. APPLIED PHYSICS LETTERS, 1999, 74 (09) : 1329 - 1331
  • [2] VLSI-NEMS chip for AFM data storage
    Despont, M
    Brugger, J
    Drechsler, U
    Dürig, U
    Häberle, W
    Lutwyche, M
    Rothuizen, H
    Stutz, R
    Widmer, R
    Rohrer, H
    Binnig, G
    Vettiger, P
    [J]. MEMS '99: TWELFTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 1999, : 564 - 569
  • [3] VLSI-NEMS chip for parallel AFM data storage
    Despont, M
    Brugger, J
    Drechsler, U
    Dürig, U
    Häberle, W
    Lutwyche, M
    Rothuizen, H
    Stutz, R
    Widmer, R
    Binnig, G
    Rohrer, H
    Vettiger, P
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 80 (02) : 100 - 107
  • [4] Future trends in hard disk drives
    Grochowski, Edward
    Hoyt, Roger F.
    [J]. IEEE Transactions on Magnetics, 1996, 32 (3 /2) : 1850 - 1854
  • [5] LUTWYCHE MI, 1998, SENS ACTUATORS A, V73, P89
  • [6] 6-MHz 2-N/m piezoresistive atomic-force-microscope cantilevers with INCISIVE tips
    Ried, RP
    Mamin, J
    Terris, BD
    Fan, LS
    Rugar, D
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1997, 6 (04) : 294 - 302
  • [7] The "Millipede" -: More than one thousand tips for future AFM data storage
    Vettiger, P
    Despont, M
    Drechsler, U
    Dürig, U
    Häberle, W
    Lutwyche, MI
    Rothuizen, HE
    Stutz, R
    Widmer, R
    Binnig, GK
    [J]. IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 2000, 44 (03) : 323 - 340
  • [8] Thermal effect limits in ultrahigh-density magnetic recording
    Weller, D
    Moser, A
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (06) : 4423 - 4439