Stenting and secondary coiling of intracranial internal carotid artery aneurysm: Technical case report

被引:152
作者
Mericle, RA
Lanzino, G
Wakhloo, AK
Guterman, LR
Hopkins, LN
机构
[1] SUNY Buffalo, Dept Neurosurg, Buffalo, NY 14209 USA
[2] SUNY Buffalo, Sch Med & Biomed Sci, Toshiba Stroke Res Ctr, Buffalo, NY 14209 USA
关键词
aneurysm; endovascular; Guglielmi detachable coils (GDCs); internal carotid artery; intracranial; pseudoaneurysm; stent;
D O I
10.1097/00006123-199811000-00130
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE AND IMPORTANCE: Endovascular stents have been successfully used in the treatment of fusiform and dissecting aneurysms of the peripheral circulation and extracranial carotid and vertebral arteries. Technical limitations related to the inability to navigate the stent and the delivery system through tortuous vascular segments has limited their application with intracranial lesions. Availability of new flexible and pliable stent systems might overcome these difficulties. CLINICAL PRESENTATION: A 49-year-old woman presented with a dissecting pseudoaneurysm of the horizontal portion of the petrous internal carotid artery that increased in size, as revealed by serial angiographic studies. INTERVENTION: The aneurysm was treated by deploying a new flexible stent across the aneurysm neck and by then packing the aneurysm sac with Guglielmi detachable coils that were delivered by a microcatheter positioned through the stent struts into the aneurysm lumen. CONCLUSION: New flexible stents can be used to treat intracranial internal carotid artery aneurysms in difficult-to-access areas, such as the horizontal petrous segment. The stent may disrupt the aneurysm inflow tract, thereby inducing stasis and facilitating intra-aneurysmal. thrombosis. In addition, the stent acts as an endoluminal scaffold to prevent coil herniation into the parent artery, which allows tight packing of even wide-necked and irregularly shaped aneurysms. The stent may also serve as a matrix for endothelial growth. We think this new generation of flexible stents and the use of this described technique will usher in the next era of endovascular management of intracranial aneurysms.
引用
收藏
页码:1229 / 1233
页数:5
相关论文
共 45 条
[11]   Endovascular stenting of internal carotid artery false aneurysm [J].
Huang, A ;
Baker, DM ;
AlKutoubi, A ;
Mansfield, AO .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (03) :375-377
[12]  
Khoja A, 1997, CATHETER CARDIO DIAG, V41, P192, DOI 10.1002/(SICI)1097-0304(199706)41:2<192::AID-CCD19>3.0.CO
[13]  
2-S
[14]  
Klein GE, 1997, AM J NEURORADIOL, V18, P1261
[15]   Embolization of wide-necked anterior communicating artery aneurysm: Technical note [J].
Levy, DI .
NEUROSURGERY, 1997, 41 (04) :979-982
[16]   Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity [J].
Lieber, BB ;
Stancampiano, AP ;
Wakhloo, AK .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (03) :460-469
[17]   Dacron-covered stent-grafts for the percutaneous treatment of carotid aneurysms: Effectiveness and biocompatibility - Experimental study in swine [J].
Link, J ;
Feyerabend, B ;
Grabener, M ;
Linstedt, U ;
Brossmann, J ;
Thomsen, H ;
Heller, M .
RADIOLOGY, 1996, 200 (02) :397-401
[18]  
Manninen HI, 1997, AM J NEURORADIOL, V18, P1216
[19]   STENT PLACEMENT FOR ARTERIAL AND VENOUS CEREBROVASCULAR-DISEASE - PRELIMINARY EXPERIENCE [J].
MARKS, MP ;
DAKE, MD ;
STEINBERG, GK ;
NORBASH, AM ;
LANE, B .
RADIOLOGY, 1994, 191 (02) :441-446
[20]   Autologous vein-covered stent repair of a cervical internal carotid artery pseudoaneurysm: Technical case report [J].
Marotta, TR ;
Buller, C ;
Taylor, D ;
Morris, C ;
Zwimpfer, T .
NEUROSURGERY, 1998, 42 (02) :408-412