Strengths and limitations of commercial tests for hepatitis C virus RNA quantification

被引:27
作者
Morishima, C
Chung, M
Ng, KW
Brambilla, DJ
Gretch, DR
机构
[1] Univ Washington, Harborview Med Ctr, Dept Pediat, Sch Med, Seattle, WA 98104 USA
[2] Univ Washington, Dept Lab Med, Sch Med, Seattle, WA 98104 USA
[3] Univ Washington, Dept Med, Sch Med, Seattle, WA 98104 USA
[4] New England Res Inst, Watertown, MA 02172 USA
关键词
D O I
10.1128/JCM.42.1.421-425.2004
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The sensitivity of the Roche COBAS Monitor v.2.0 test was slightly better than that of the Bayer bDNA 3.0 test, but the Monitor test underquantified specimens by 2.5- to 10.6-fold even at relatively low hepatitis C virus RNA concentrations. Dilution prior to assay minimally decreased the reproducibility of the Monitor assay, leading to the recommendation for all specimens to be diluted 1:100 prior to testing by this assay.
引用
收藏
页码:421 / 425
页数:5
相关论文
共 23 条
[1]   Performance of the new Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: Conversion to international units and comparison with the Roche COBAS amplicor HCV monitor, version 2.0, assay [J].
Beld, M ;
Sentjens, R ;
Rebers, S ;
Weegink, C ;
Weel, J ;
Sol, C ;
Boom, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (03) :788-793
[2]   Interferon alfa-2b alone or in combination with ribavirin for the treatment of relapse of chronic hepatitis C [J].
Davis, GL ;
Esteban-Mur, R ;
Rustgi, V ;
Hoefs, J ;
Gordon, SC ;
Trepo, C ;
Shiffman, ML ;
Zeuzem, S ;
Craxi, A ;
Ling, MH ;
Albrecht, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (21) :1493-1499
[3]   Accurate quantification of hepatitis C virus (HCV) RNA from all HCV genotypes by using branched-DNA technology [J].
Detmer, J ;
Lagier, R ;
Flynn, J ;
Zayati, C ;
Kolberg, J ;
Collins, M ;
Urdea, M ;
SanchezPescador, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (04) :901-907
[4]   Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma [J].
Erice, A ;
Brambilla, D ;
Bremer, J ;
Jackson, JB ;
Kokka, R ;
Yen-Lieberman, B ;
Coombs, RW .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (08) :2837-2845
[5]   Peginterferon alfa-2a plus ribavirin for chronic hepatitis C virus infection. [J].
Fried, MW ;
Shiffman, ML ;
Reddy, KR ;
Smith, C ;
Marinos, G ;
Goncales, FL ;
Haussinger, D ;
Diago, M ;
Carosi, G ;
Dhumeaux, D ;
Craxi, A ;
Lin, A ;
Hoffman, J ;
Yu, J .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (13) :975-982
[6]  
Germer JJ, 2002, J CLIN MICROBIOL, V40, P1885
[7]   Comparative evaluation of the VERSANT HCV RNA 3.0, QUANTIPLEX HCV RNA 2.0, and COBAS AMPLICOR HCV MONITOR version 2.0 assays for quantification of hepatitis C virus RNA in serum [J].
Germer, JJ ;
Heimgartner, PJ ;
Ilstrup, DM ;
Harmsen, WS ;
Jenkins, GD ;
Patel, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (02) :495-500
[8]   Interferon treatment for chronic hepatitis C infection in hemophiliacs - Influence of virus load, genotype, and liver pathology on response [J].
Hanley, JP ;
Jarvis, LM ;
Andrews, J ;
Dennis, R ;
Hayes, PC ;
Piris, J ;
Lee, R ;
Simmonds, P ;
Ludlam, CA .
BLOOD, 1996, 87 (05) :1704-1709
[9]   SERIAL ASSAY OF HEPATITIS-C VIRUS-RNA IN SERUM FOR PREDICTING RESPONSE TO INTERFERON-ALPHA THERAPY [J].
HINO, K ;
OKUDA, M ;
KONISHI, T ;
ISHIKO, H ;
OKITA, K .
DIGESTIVE DISEASES AND SCIENCES, 1995, 40 (01) :14-20
[10]  
Karino Y, 1997, AM J GASTROENTEROL, V92, P61