Clinical results using the trochanter stabilizing plate (TSP): The modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures

被引:76
作者
Babst, R [1 ]
Renner, N [1 ]
Biedermann, M [1 ]
Rosso, R [1 ]
Heberer, M [1 ]
Harder, F [1 ]
Regazzoni, P [1 ]
机构
[1] Univ Basel, Dept Surg, Div Traumatol, CH-4031 Basel, Switzerland
关键词
unstable intertrochanteric fracture; dynamic hip screw (DHS); trochanter stabilizing plate (TSP);
D O I
10.1097/00005131-199808000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate whether the implantation of the modular trochanter stabilizing plate (TSP) in addition to the dynamic hip screw (DHS) prevents excessive telescoping and Limb shortening in four-pad and selected three-part trochanteric fractures. Design: Prospective clinical study. Setting: The study was conducted at the trauma unit of the Surgical Department of the University of Basel, Switzerland. Patients: Forty-six consecutive patients with unstable intertrochanteric fractures were treated with an additional TSP superimposed on the regular DHS at our institution between July 1991 and July 1993. Five patients died before the first follow-up, one patient was lost to follow-up, and another patient refused followup. Thus, thirty-nine patients were followed for at least twelve months (mean 14 months, range 12 to 20 months). Intervention: The fractures treated were classified according to the OTA classification, which is based on the AO classification. Seventeen were 31-A2.2, seven were 31-A2.3, and fourteen were 31-A3.3 fractures. Results: Lateralization of the greater trochanter was successfully prevented in all fractures. Limited fracture impaction was found in 90 percent (n = 35) of the patients with telescoping of 9.5 millimeters (range 0 to 30 millimeters), resulting in mean limb shortening of 5.37 millimeters (range 0 to 14.9 millimeters). Four patients suffered limb shortening exceeding fifteen millimeters (range 15.6 to 21.3 millimeters). Functional results were excellent and good in 87 percent of patients and fair in 13 percent according to the Salvati-Wilson score. All fractures had healed six months after the operation. Three complications required a secondary procedure: one from not inserting a second screw parallel to the gliding hip screw to prevent rotation of the head-neck fragment ("antirotation screw"), one because of deep infection, and one because of a refracture after premature implant removal. Conclusion: In unstable pertrochanteric fractures with small or missing lateral cortical buttress, the addition of a TSP to the DHS effectively supports the unstable greater trochanter fragment and can prevent rotation of the head-neck fragment. Excessive fracture impaction and consecutive limb shortening was prevented by this additional implant in 90 percent of these patients.
引用
收藏
页码:392 / 399
页数:8
相关论文
共 26 条
[1]  
BABST R, 1993, SCHWEIZ MED WSCHR, V123, P566
[2]   THE EFFECT OF ADJUNCTIVE METHYLMETHACRYLATE ON FAILURES OF FIXATION AND FUNCTION IN PATIENTS WITH INTERTROCHANTERIC FRACTURES AND OSTEOPOROSIS [J].
BARTUCCI, EJ ;
GONZALEZ, MH ;
COOPERMAN, DR ;
FREEDBERG, HI ;
BARMADA, R ;
LAROS, GS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1094-1107
[3]   ANTIBIOTIC-PROPHYLAXIS WITH 2 DOSES OF CEPHALOSPORIN IN PATIENTS MANAGED WITH INTERNAL-FIXATION FOR A FRACTURE OF THE HIP [J].
BODOKY, A ;
NEFF, U ;
HEBERER, M ;
HARDER, F .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (01) :61-65
[4]  
BONNAIRE F, 1992, UNFALLCHIRURG, V95, P246
[5]   FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[6]   THE GAMMA-NAIL - A SIGNIFICANT ADVANCE OR A PASSING FASHION [J].
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :329-331
[7]   TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURES OF THE FEMUR - A PROSPECTIVE TRIAL COMPARING ANATOMICAL REDUCTION AND VALGUS OSTEOTOMY [J].
CLARK, DW ;
RIBBANS, WJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1990, 21 (02) :84-88
[8]   Management of unstable trochanteric fractures (type A0 A3) with the use of the sliding hip screw and a new connectable butt-press plate [J].
David, A ;
Hufner, T ;
Lewandrowski, KU ;
Pape, D ;
Muhr, G .
CHIRURG, 1996, 67 (11) :1166-1173
[9]   UNSTABLE INTERTROCHANTERIC FRACTURE OF THE FEMUR - A PROSPECTIVE RANDOMIZED STUDY COMPARING ANATOMICAL REDUCTION AND MEDIAL DISPLACEMENT OSTEOTOMY [J].
DESJARDINS, AL ;
ROY, A ;
PAIEMENT, G ;
NEWMAN, N ;
PEDLOW, F ;
DESLOGES, D ;
TURCOTTE, RE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (03) :445-447
[10]  
DOPPELT SH, 1980, J ORTHOP TRAUMA, V7, P348