Management of unstable trochanteric fractures (type A0 A3) with the use of the sliding hip screw and a new connectable butt-press plate

被引:15
作者
David, A
Hufner, T
Lewandrowski, KU
Pape, D
Muhr, G
机构
[1] Chir. Univ. Klin. und Poliklinik, Berufsgenossenschaftliche K., Bochum
[2] Chir. Univ. Klin. und Poliklinik, BG-Kliniken Bergmannsheil, D-44789 Bochum
来源
CHIRURG | 1996年 / 67卷 / 11期
关键词
trochanteric fractures; open reduction; internal fixation; dynamic hip screw; trochanteric butt-press plate;
D O I
10.1007/s001040050120
中图分类号
R61 [外科手术学];
学科分类号
摘要
ORIF management of unstable trochanteric fractures of type A3 of the A0 classification is difficult because of lateral dislocation of the proximal fractured segments, particularly when only the sliding hip-screw is used for fixation. A connectable butt-press plate was recently developed in order to prevent this type of dislocation. We review the results with this fixation technique in 22 elderly patients with an average age of 76 years who presented with highly unstable trochanteric fracture of the A3 type. Three patients died of diseases unrelated to the trauma or operation before the fractures had healed. The other 19 were followed prospectively until fracture healing had occurred. Complaints, leg shortening and changes in the CCD angle were recorded. Furthermore, the mobility score was determined. Although the patients were able to bear full weight after the operation, no lateral dislocation of fragments was observed. Only 1 patient had a varus dislocation of 5'' until the fracture had consolidated. This was due to severe osteopenia and subsequent dislocation of the screw within the femoral head. No pseudarthrosis, osteitis or rotational malalignment was noted. Five of the surviving patients had a lower mobility score after fracture healing as compared to the status before the fracture was sustained. On the basis of this review we recommend the use of this new connectable buttress plate with sliding hip screws because it provides sifficient fixation of highly unstable fractures of type A3.
引用
收藏
页码:1166 / 1173
页数:8
相关论文
共 32 条
[1]
GAMMA-NAIL VS COMPRESSION SCREW FOR TROCHANTERIC FEMORAL FRACTURES - 15 REOPERATIONS IN A PROSPECTIVE, RANDOMIZED STUDY OF 378 PATIENTS [J].
AUNE, AK ;
EKELAND, A ;
ODEGAARD, B ;
GROGAARD, B ;
ALHO, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :127-130
[2]
BABST R, 1993, SCHWEIZ MED WSCHR, V123, P566
[3]
BONNAIRE F, 1992, UNFALLCHIRURG, V95, P246
[4]
Boriani S., 1994, Chirurgia degli Organi di Movimento, V79, P193
[5]
PROXIMAL FEMORAL FRACTURES - A BIOMECHANICAL STUDY TO COMPARE INTRAMEDULLARY AND EXTRAMEDULLARY FIXATION [J].
CURTIS, MJ ;
JINNAH, RH ;
WILSON, V ;
CUNNINGHAM, BW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1994, 25 (02) :99-104
[6]
A BIOMECHANICAL EVALUATION OF AN INTRAMEDULLARY FIXATION DEVICE FOR INTERTROCHANTERIC FRACTURES [J].
FLAHIFF, CM ;
NELSON, CL ;
GRUENWALD, JM ;
HOLLIS, JM .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 35 (01) :23-27
[7]
Forthomme J P, 1993, Acta Orthop Belg, V59, P22
[8]
FRIEDL W, 1994, CHIRURG, V65, P953
[9]
Geissler N, 1994, Unfallchirurgie, V20, P72, DOI 10.1007/BF02588146
[10]
GEISSLER N, 1992, ZBL CHIR, V117, P355